Controlling the
Repeated Playback of Phrases (Interval Playback)
The specified phrase will be played back at fixed intervals. Make each of the terminal settings beforehand for the playback interval and phrases to be played back.
When making settings in Interval Playback mode, assign Phrases 1 through 9 to the control output connectors 1 through 9.
The playback interval settings are shown below.
Port No. | Playback Interval |
1 | 1 second |
2 | 5 seconds |
3 | 10 seconds |
4 | 15 seconds |
5 | 30 seconds |
6 | 1 minute |
7 | 5 minutes |
8 | 15 minutes |
9 | 30 minutes |
Operational Specifications of Interval Playback
Basic Operation of Interval Playback
modes (PLAYBACK BY CARD DATA/DIRECT PLAYBACK/BINARY PLAYBACK/INTERVAL PLAYBACK).
You cannot achieve control input playback merely by connecting a device to the port. Be sure to set the control input mode and match the method used for connecting to the connectors.
Procedure for Setting the Control Input Mode
1.Turn off the power of the
2.Set the MODE switches on the
SW1: ON
SW2: ON
3.Turn on the power of the
*Use a pointed object to change the ON/OFF settings of the MODE switches.
Controlling Recording with the Control Connectors (Terminal Rec)
What is Terminal Rec/Use and Applications
fig.inp-21
Port No. 2
STOP Port
AUDIO OUTPUT
0002 |
| 0002 |
|
|
|
0002 interrupted
You can specify phrases by inputting binary (base 2) signals to the Port Nos. 1 through 8, and perform record, playback, and erase functions by inputting control signals to Port Nos. 9 and 10. A total of 250 phrases can be specified with control signals (On/Off). This is convenient when you want to
Interval time used for phrases
[Interval time used for phrases]
Playback:
Input control signals to the control Input/output connectors No. 1 through 9.
→Results in the repeated play of the phrase assigned to the terminal.
stopping:
Input a control signal to Port No. 10 (STOP).
→This stops playback of the phrase.
AR-200 Settings
Selecting the Control Input Mode
Set the MODE switches on the
control recording from an external control device.
fig.inp-22
Binary Specification
Port
8 7 6 5 4 3 2 1
01110000
Signal sent to Port | Phrase112 |
|
|
| Record |
|
|
| |||
Nos. 9 and 10 |
|
|
| ||
|
|
|
| Play | |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
|
Delete
[Signal sent to Port Nos. 9 and 10]
*To conduct binary control, you need to provide a control device that can generate binary signals.
*Input of binary specifications should be completed in no more than 50 milliseconds.
34