MIDI Implementation

*Not received when recording mode is not “Standby”.

*The same processing will be carried out as when Start is received.

Stop

status

FCH

*Not received when recording mode is not “record”.

3.4Messages received for detecting trouble in MIDI connection.

System Realtime message

Active Sensing

Status

FEH

*When Active Sensing is received, the unit will begin monitoring the intervals of all further messages. While monitoring, if the interval between messages exceeds 400 ms, the same processing will be carried out as when All Sounds Off, All Notes Off and Reset All Controllers are received, and message interval monitoring will be halted.

4. Transmit data (MIDI Recorder Section)

When AR-200/3000 is in MIDI Recorder mode, MIDI Messages is not transmitted.

5. Exclusive Communication

Exclusive message model IDs that can be used on the AR-200 and AR-3000 are OOH, 38H (AR-200), 00H, and 37H (AR-3000). The Device Id can be set to 00H to 1FH.

Only received when AR-200/3000 is in Media Player Section.

Data Set 1 DT1 (12H)

Byte

Description

F0H

Status of System Exclusive Message

41H

Universal System Exclusive Message Real time Header

dev

device ID (dev : 00H--1FH)

mdl

Model ID (mdl : 00H, 38H) AR-200

 

(mdl : 00H, 37H) AR-3000

12H

Command ID (DT1)

aaH

address MSB

:

:

ddH

Address LSB

eeH

Data

:

:

llH

Data

sum

Check Sum

F7H

EOX (End of System Exclusive Message)

5.1 Parameter Address Map

This map indicates address,size, data (range), Parameter, Description,and default Value of parameters which can be transferred using "Data Set1(DT1)."

All the numbers of address, size, Data, and default Value are indicated in 7-bit Hexadecimal-form.

(AR-200 Model ID=00H,38H)

(AR-3000 Model ID=00H,37H)

Address Block Map

An outlined address map of the Exclusive Communication is as follows;

Exclusive Address Table

for recording setting

(Only AR-3000)

Address(H) SIZE(H)

DATA(H)

Parameter

Description

===================================================================

00 00 10

00 00 08

00

- 07

Phrase Number

upper 4bits

11#

 

00

- 7f

Phrase Number

lower 7bits

12#

 

00

- 04

Grade

0:ANNOUNCE

 

 

 

 

 

1:LONG2

 

 

 

 

 

2:LONG1

 

 

 

 

 

3:STANDARD

 

 

 

 

 

4:HIGH

 

 

 

 

 

5:S-HIGH

 

 

 

 

 

6:NASTER

13#

 

00

- 02

R-DAC mode

0:Linear

 

 

 

 

 

1:Mode1

 

 

 

 

 

2:Mode2

 

 

 

 

 

3:Mode3

 

 

 

 

 

4:H-LINEAR

14#

 

00

- 01

REC type

0:MONO

 

 

 

 

 

1:STEREO

15#

00 - 03

REC Trigger Level

0:OFF

 

 

 

1:LOW

 

 

 

2:MID

 

 

 

3:HIGH

16#

00 - 02

REC Source

0:ANALOG-IN

 

 

 

1:DIGITAL-IN

 

 

 

2:MIDI-IN

17#

00 - 01

TimeBase

0:192

 

 

 

1:240

===================================================================

Phrase number

DATA(H)

A0001-A1000

00 00

- 07 67

B0001-B1000

07 68

- 0H 4F

*Only received packet data.

*When reception of this packet is completed, the AR-3000 goes into REC PAUSE mode. However, if the phrase already exists, the AR-3000 ignores this SysEx message.

(AR-2000 compatible)

 

 

 

Address(H) SIZE(H)

DATA(H)

Parameter

Description

===================================================================

00 00 00

00 00 08

00

- 07

Phrase Number

upper 3bits

01#

 

00

- 7f

Phrase Number

lower 7bits

02#

 

00

- 04

Grade

0:ANNOUNCE

 

 

 

 

 

1:LONG2

 

 

 

 

 

2:LONG1

 

 

 

 

 

3:STANDARD

 

 

 

 

 

4:HIGH

03#

 

00

- 02

R-DAC mode

0:Linear

 

 

 

 

 

1:Mode1

 

 

 

 

 

2:Mode2

04#

 

00

- 01

REC type

0:MONO

 

 

 

 

 

1:STEREO

05#

 

00

- 03

REC Trigger Level

0:OFF

 

 

 

 

 

1:LOW

 

 

 

 

 

2:MID

 

 

 

 

 

3:HIGH

06#

 

00

- 01

REC Source

0:ANALOG-IN

 

 

 

 

(MIDI REC OFF)

 

 

 

 

 

1:MIDI-IN

 

 

 

 

(MIDI REC ON)

07#

 

00

- 01

TimeBase

0:192

 

 

 

 

 

1:240

===================================================================

Phrase number

DATA(H)

A0001 - A0500

00 00 - 03 73

B0001 - B0500

03 74 - 07 67

*Only received packet data.

*When reception of this packet is completed, the AR-3000 goes into REC PAUSE mode. However, if the phrase already exists, the AR-3000 ignores this SysEx message.

62

Page 62
Image 62
Roland AR-200 owner manual Messages received for detecting trouble in Midi connection, Transmit data Midi Recorder Section