143
Editing Songs
Continuously variable controllers such as aftertouch, pitch bend, and
expression tend to create unexpectedly large amounts of data when
operated. Data Thin will strip out redundant data to increase the
amount of memory available for the sequencer.
For details on the settings, refer to
Basic Operation for Track
Editing
(p. 133).
fig.DataThin
The phrase tracks or patterns will be exchanged in their entirety.
For details on the settings, refer to
Basic Operation for Track
Editing
(p. 133).
fig.Exchange
TRK 1–16:
Specified phrase track
PTN001–100:
Specified pattern
This function calculates the playback time of a song or allows you to
modify the tempo track data so that the song will play back in a
specified time.
For details on the settings, refer to
Basic Operation for Track
Editing
(p. 133).
fig.TimeFit
* Time Original: Current playback time
Thinning Out the Sequencer Data (Data Thin)
Parameter Value Explanation
Track/
Pattern
TRK ALL,
TRK 1–16,
PTN001–100
Phrase track(s) or pattern
whose sequencer data will be
thinned
TRK ALL:
Phrase tracks 1–16
TRK 1–16:
Specified phrase track
PTN001–100:
Specified pattern
Ch/Part ALL, Ch 1–16 MIDI channel of the data to be
thinned
ALL:
Thins all sequencer data.
Ch 1–16:
Thins sequencer data of just one spe-
cific MIDI channel.
Measure 0001– Range of measures whose se-
quencer data will be thinned
If you set “For” to “ALL,”
all measures will be speci-
fied.
For 1–ALL
Data Thin
Value
0–99 For thinning data which incor-
porates rapid changes, use
higher settings.
Data Thin
Time
1–999 If you are thinning data that
changes gradually over time,
use higher settings.
Status ALL,
Poly Aftertouch,
Control Change,
Channel After-
touch,
Pitch Bend
Type of data to be thinned
When “Status” is “Poly Aftertouch”
Range Min 0 (C -)–127 (G9) Range of note numbers to be
thinned
You can also specify the key
range by pressing keys on
the keyboard.
Range Max
When “Status” is “Control Change”
Range Min 0–127 Range of controller numbers
to be thinned
Range Max
Swapping Two Phrase Tracks or Patterns (Exchange)Adjusting the Song’s Playback Time (Time Fit)
Parameter Value Explanation
Measure 0001– Measure the playback time,
or check/modify the range
of measures to be adjusted.
If you set “For” to “ALL,”
all measures will be speci-
fied.
For 1–ALL
Time H/M/S The playback time will be
displayed.
From left to right, the time
display indicates “hours:
minutes: seconds.”
Fantom-Xa_e.book 143 ページ 2004年10月22日 金曜日 午後2時3分