Settings Common to All Modes (System Function)
[F1 (GENERL)]System Menu [F3 (MIDI)]
Parameter Value Explanation
Local Switch OFF, ON Determines whether the internal sound generator is disconnected (OFF) from the controller sec-
tion (keyboard, Pad, pitch bend/modulation lever, knobs, buttons, D Beam controller, pedal,
and so on); or not disconnected (ON).
Normally this is left “ON,” but if you wish to use the Fantom-Xa’s keyboard and controllers
to control only external sound modules, set it to “OFF.”
Device ID 17–32 When you want to transmit or receive System Exclusive messages, set this parameter to match
the Device ID number of the other MIDI device.
Remote Keyboard
Switch
OFF, ON Set this parameter “ON” when you want to use an external MIDI keyboard instead of the Fan-
tom-Xa’s keyboard.
In this case, the MIDI transmit channel of the external MIDI keyboard can be set to any chan-
nel. Normally you will leave this parameter “OFF.”
* Turn this “ON” when you want to control the Fantom-Xa from an external MIDI device when per-
forming with the Arpeggio or RPS function.
Performance Con-
trol Channel
1–16, OFF Selects the MIDI receive channel used during switching of performances when MIDI messages
(Program Change/Bank Select) are sent from an external MIDI device.
Set this to “OFF” if performances are not to be switched from an external MIDI device.
* If only a program change is received, and if this parameter setting coincides with the MIDI receive
channel of a part, priority will be given to switching the performance.
Kbd Patch Rx/Tx
Channel
1–16 Channel used to transmit and receive MIDI messages for the Keyboard part in Patch mode
Pad Patch Rx/Tx
Channel
1–16 Channel used to transmit and receive MIDI messages for the Pad part in Patch mode
Using the Local Switch
When you’re using the Fantom-Xa with external sequencer
software, leave the Local Switch turned off. Read the following
for details.

Connecting the Fantom-Xa to an external

sequencer

fig.LocalSw.e
Typically, things are hooked up so the data travels as follows:
the Fantom-Xa’s keyboard your external sequencer software
the Fantom-Xa’s sound generator. Normally, the Fantom-
Xa’s keyboard section is internally connected to its sound
generator section; this internal connection is controlled by the
Local Switch. If you turn the Local Switch off, the Fantom-Xa’s
keyboard and sound generator sections will be independent,
allowing you to use the connection described above with your
external sequencer software.
Keyboard
Sequencer
Sound Generator

Local Off

(External)
Fantom-Xa Fantom-Xa
Fantom-Xa_e.book 197 ページ 2004年10月22日 金曜日 午後2時3分