SAMPLE CONFIGURATIONS
MULTIPLE CONTROLLERS WITH ONE TUNER
Sharing a single CAM6.6T (internal tuner) with multiple controllers
This arrangement can support up to six CAM6.6 units for up to 36 zones/6 sources. Each additional CAM6.6 must have an incremental Controller ID # and RNET link. Audio from the source tuner can be split if shared by all controllers.
CAM6.6T -
Controller Setup Menu: Controller ID = 1
Peripheral Setup Menu: Controller ID = All Controllers
Output/Input Switch = Internal Source Output RCA cable connected to Source 1
CAM6.6 (no tuner installed) - Controller Setup Menu: Controller ID = 2 Source Setup Menu: Basic Setup Procedure: Source # = 1; Source Name = Tuner; Command Type = Peripheral
Output/Input Switch = Input
RCA cable connected to Source 1
102.5 | 102.5 | 102.5 |
CAM6.6 Back Panel (Controller ID 1)
CAM6.6
RCA Cables
102.5 | 102.5 | 102.5 |
CAM6.6 Back Panel (Controller ID 2)
CAM6.6
103