installation

Safety instructions for the installation

This oven may be installed only by an approved electrician. The installer is responsible for connecting the appliance to the main supply, while observing the relevant safety regulations.

Ensure protection from live parts when installing the oven.

The kitchen cabinet in which the oven is built in must satisfy stability requirements as specified in DIN 68930.

Power connection

If the appliance is not connected to the mains with a plug, a multi-pole isolator

 

 

 

switch (with at least 3 mm contact spacing) must be provided in order to satisfy

 

 

 

safety regulations. The power cable (H05 RR-F or H05 VV-F, min., 1.5-2.5 mm²)

 

 

 

must be of sufficient length to be connected to the oven, even if the oven stands

 

 

 

on the floor in front of its built-in cabinet. Open the rear connection cover of

 

 

 

the oven with a screwdriver and loosen the screws of the cable clamp before

 

 

 

you connect the power lines to the relevant connection terminals. The oven is

BROWN

BLUE or

YELLOW

earthed via the (

)-terminal. The yellow and green cable(earth connection)

or BLACK

WHITE

and GREEN

must be connected first and be longer than the others. If the oven is connected

 

 

 

to the mains with a plug, this plug must remain accessible after the oven is installed.

Samsung will take no responsibility for accidents that originate from a missing or faulty earth connection.

WARNING: Do not allow the connecting cable to become trapped during installation, and prevent it coming into contact with hot parts of the oven.

Installation in the cabinet

With built-in furniture, plastic surfaces and adhesive for the oven should be resistant to 90 °C inside of the furniture and to 75 °C for adjacent furniture. Samsung will take no responsibility for damage of plastic surfaces or adhesive from the heat.

i tons ruc ynstti safe

1

 

547

 

 

 

560

 

 

 

 

 

595

 

 

572

 

 

 

 

 

 

595

21

 

 

 

 

 

3

 

 

min. 560

 

min. 550

 

min. 50

min. 600

 

Lower element

 

2

Lower

 

Top

 

element

 

element

Airflow through the ventilation gap

4

 

 

 

 

min. 590

50

min. 550

-max. 600

 

 

min. 560

Top element

There should be a ventilation gap in the base of the kitchen cabinet where the oven is to be placed. For ventilation, a gap of about 50mm should be left between the lower shelf and the supporting wall. If the oven is to be installed below a hob, the hob’s installation instructions should be followed.

5

Push the appliance completely into the cabinet and fix the oven firmly on both sides using 2 screws. Make sure that a gap of at least 5mm should be left between the appliance and the adjacent cabinet.

After installation, remove the vinyl protective film, tape, paper and accessories from the door and inside of oven. Before uninstalling the oven from the furniture, disconnect the oven from the power supply and release the 2 screws on the both sides of the oven.

WARNING: The built-in furniture must have a minimum ventilation gap for Air-flow as shown on picture. Do not cover this hole with strips of wood, for this is used to provide ventilation.

The front exterior of the oven such as handle is different model by model. But the size of the oven in the picture is same.

safety instructions_7

NV6323BGSSR_OL_DG68-00496D_EN.indd 7

11/03/2013 15:44:46

Page 151
Image 151
Samsung NV6323BGSSR/OL Installation, Power connection, Safety instructions for the installation, Safety instructions7