3-18
E
3-17
And assign the user PCs window network setting as following example.
Example) IP: 192.168.1.201
Subnet mask: 255.255.255.0
Gateway: 192.168.1.1
Execute the IPinstaller.exe in user PC and verify the IP, Subnet Mask and
Gateway connected to the SCC-C6475(P).
After completing the IP setting in the IPinstaller, enter the password and
click the Apply button. And the SCC-C6475(P) will reboot automatically.
Password is the root users log in Password to access the
SCC-C6475(P).
Password is set as basic value 4321 when it is shipped.
User access http://192.168.1.200 by using the PC internet browser.
If the indicated content in the camera list is not the same as follows, fix the
setting as the follow Example.
Example) <SCC-C6475(P)> <User PC>
IP: 192.168.1.200 IP: 192.168.1.201
Subnet mask: 255.255.255.0 Subnet mask: 255.255.255.0
Gateway: 192.168.1.1 Gateway: 192.168.1.1
HTTP Port: 80
Accessing SCC-C6475(P) by using the internet browser, Log In page
as follow appears.
Log in at SCC-C6475(P) and the main screen that user can see
images appears.
After checking if the camera image works well, click the setup mode
button in the right up side of the main screen.
- User ID to Log In is set to a basic value root when it was shipped
and the password is 4321.