Lamp Replacement

Cautions on Lamp Replacement

Projector lamp requires replacement after.

Use the recommended lamp when replacing. Lamp specifications are defined in the user’s manual. Replace with the same model provided with the projector.

-Lamp Model Name : LAMP-MERCURY-Philips

-Lamp Manufacture : Philips Lighting

- Lamp Life Time

: 2000Hrs

- Lamp Type

: 250W UHP

- Lamp Part Number : BP47-00010A

Check that the power cord is unplugged before replacing lamps.

Wait for at least 30 minutes before replacing lamps to cool off the lamp unit after disconnecting power.

Lamp is a high-pressure product. Do not place near flammable materials or children.

Remove dirts or foreign materials around or inside the lamp unit using a proper vacuum device.

Be careful not to touch the lamp itself when handling the lamp unit.

If the lamp is poorly handled, it may result in poor picture quality or shorter life time of lamp.

The projector is will not operate normally if the cover is not locked completely after lamp replacement. Refer to LED information in the user’s manual if the projector does not operate normally.

Lamp Replacement Procedure

1 Detach the screw of the

2 Push to open the lamp

3 Detach the three screws.

lamp cover.

cover in the direction of

 

 

the arrow.

 

Other Information

Lamp Replacement

4Lift and grip the lamp handle in the direction of the arrow and pull it out.

5 Reverse the disassembly

The Lamp is high-

procedure to assemble the

 

temperature high-

unit after replacement.

NOTE

pressure product.

 

 

 

 

Wait for at least 30

 

 

minutes to proceed after

 

 

disconnecting power.

 

Be sure that the power

 

 

cord is disconnected

 

 

before proceeding.