Recording
BCONTINUOUS recording
1Recording starts automatically when this unit is turned on.
"C" is displayed on the screen. The connected cameras are simultaneously recorded.
The recording mode can be changed using RECORDING under RECORD settings. Settings, such as image quality, can also be set. (P27)
2% 2006/07/14 09:04:54
CH1 | C | CH2 | C |
CH3 | C | CH4 | C |
2To stop recording, select RECORDING under RECORD settings using the control button ({) and select "DISABLE" using the control button (}~).
“C” disappears.
RECORD |
|
RESOLUTION | QUAD |
CHANNEL | CH1 |
FRAME RATE | 1 f/s |
QUALITY | NORMAL |
RECORDING | DISABLE |
MOTION ZONE | FULL ZONE |
MOTION SENSITIVITY | 7 |
SENSOR TYPE | |
PRE RECORD | ON |
POST EVENT RECORD | 5 SECONDS |
ALARM | OFF |
ALARM DURATION | 5 SECONDS |
AUDIO | OFF |
TIMER SET |
|
CBY MOTION recording
A motion sensor can be set for each channel.
1Adjusting the following settings using the control button ({}~).
• | RESOLUTION | • | FRAME RATE |
• | CHANNEL | • | QUALITY |
2Select RECORDING using the control button ({) and select BY MOTION using the control button (}~).
3Select MOTION ZONE using the control button ({) and select the PARTIAL ZONE using the control button (}~), press the ENTER button.
The motion setting screen is displayed.
• PARTIAL ZONE | • FULL ZONE |
If FULL ZONE is selected, the motion setting screen is not displayed. Only set the level of sensitivity for MOTION SENSITIVITY.
RECORD |
|
RESOLUTION | QUAD |
CHANNEL | CH1 |
FRAME RATE | 1 f/s |
QUALITY | NORMAL |
RECORDING | BY MOTION |
MOTION ZONE | PARTIAL ZONE |
MOTION SENSITIVITY | 7 |
SENSOR TYPE | |
PRE RECORD | ON |
POST EVENT RECORD | 5 SECONDS |
ALARM | OFF |
ALARM DURATION | 5 SECONDS |
AUDIO | OFF |
TIMER SET |
|
Detection frame
4Select the sensor detection position using the control button ({}~) and press the ENTER button.
The frame set for the sensor detection is grainy. Select a sensor detection position by repeating the operation.
5Select MOTION SENSITIVITY using the control button ({) and select the level of sensitivity using the control button (}~).
Selections:
6Select PRE RECORD using the control button ({) and select the pre recording as necessary using the control button (}~).
7Select POST EVENT RECORD using the control button ({) and select the recording time as necessary using the control button (}~).
Selections: 2 - 30 SECONDS
8Press the EXIT/STOP button once operations are complete.
Press the EXIT/STOP button repeatedly to return to the live video.