LIVE settings

Press the MENU button and enter the password. (P24)

The MAIN MENU is displayed, select "LIVE" using the control button ({}~).

MAIN MENU

 

LIVE

 

RECORD

SYSTEM

NETWORK

HDD SET

SERVICE

 

 

 

 

 

 

 

LIVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OSD

ON

A

 

 

 

 

 

SEQUENCE

OFF

 

 

 

 

 

SEQ-DWELL TIME

2 SECONDS

 

 

 

 

 

 

EVENT BEEP

OFF

B

 

 

 

 

 

OSD CONTRAST

 

 

 

80

 

 

 

 

 

CHANNEL

CH1

 

 

 

 

 

DISPLAY

ON

 

 

 

 

 

 

SEQ LIST

ON

 

 

 

 

 

 

BRIGHTNESS

 

 

 

 

50

 

 

 

 

 

 

CONTRAST

 

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

HUE

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

SATURATION

 

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

VGA SCREEN MODE

FULL

 

 

 

 

 

 

ERROR ALARM

OFF

bFunction of the menu operation button

1 2 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 5

6

7

1MENU: Press to display the MAIN MENU.

2 {: Press to move the cursor upward.

3EXIT/STOP: Press repeatedly once the menu operations are complete.

4 }: Press to select a setting value.

5ENTER: Press to enter the setting screen, select and confirm.

6 : Press to move the cursor down.

7 ~: Press to select a setting value.

ASetting the OSD and OSD CONTRAST

Displays information such as the date and camera channel and sets the character contrast on the screen.

1Select OSD using the control button ({) and select ON/OFF using the control button (}~).

ON: The date and time, as well as the channel, are displayed on the screen.

OFF: Characters and symbols are not displayed (Except for the recording symbol).

2Select OSD CONTRAST using the control button ({) and adjust the character contrast using the control button (}~).

The display bar (20-100) changes and the contrast of the real time character display changes.

BSetting the SEQUENCE and SEQ-DWELL TIME

To set the sequence and the sequence interval of the screen.

1Select SEQUENCE using the control button ({) and select ON using the control button (}~).

ON: Sequencing is performed on a single-screen (When live).

OFF: Sequencing is not performed.

2Select SEQ-DWELL TIME using the control button ({) and select a sequence interval using the control button (}~).

Selections: 1, 2, 3 - 58, 59, 60 SECONDS

CSetting the EVENT BEEP

To set the alarm sound when motion is detected or the alarm is triggered.

1Select EVENT BEEP using the control button ({) and select ON/OFF using the control button (}~).

ON: The alarm sound is triggered when the alarm is triggered

OFF: The alarm sound is not triggered

25