Maintenance and Care

Lamp Replacement

When the projection lamp of the projector reaches its end of life, the Lamp replacement icon appears on the screen and LAMP 1/2 REPLACE indicator lights orange. Replace the lamp with a new one promptly. The timing when the LAMP 1/2 REPLACE indicators should light is depending on the lamp mode.

Indicators

Lamp replacement icon

LAMP 1 / 2 REPLACE indicators

Note:

•The Lamp replacement icon will not appear when the Display function is set to “Off” (p.53), or during “Freeze” (p.30).

Follow these steps to replace the lamp.

WARNING:

TURN OFF THE UV LAMP BEFORE

OPENING THE LAMP COVER.

Allow the projector to cool, for at least 45 minutes before you open Lamp Cover. The inside of the projector can become very hot.

CAUTION

For continued safety, replace with a lamp assembly of the same type.

Do not drop the lamp assembly or touch a glass bulb! The glass can shatter and may cause injury.

1

Check the number of lamp to be replaced on the Lamp

 

Status Display.

2

Turn off the projector, press the Main On/Off Switch to Off

 

and unplug the AC power cord from the AC outlet. Let the

 

projector cool for at least 45 minutes.

3

Loosen a screw on the Lamp Cover. Slide and open the

 

Lamp Cover. (See the right figure.)

4

Loosen two screws and pull out the Lamp to be replaced

 

by grasping handle.

5

Replace the Lamp with a new one and tighten two

 

screws. Make sure the Lamp is set properly.

6

Put the Lamp Cover back and tighten a screw.

LAMP

 

COVER

SCREW

 

LAMP 2

CAUTION : DO NOT OPERATE The projector WHILE ANY OF LAMPS IS REMOVED. IT MAY RESULT IN MALFUNCTIONS, FIRE HAZARD, OR OTHER ACCIDENTS.

NOTES ON LAMP REPLACEMENT

To maintain quality of picture (better balance of color and brightness in entire screen), we recommend replacing both 2 lamps at a time.

SCREWS

LAMP 1

 

Make sure which number of lamp needs to be replaced on Lamp Status Display.

Figure shows case of replacing LAMP 1.

75