98
Appendix
Status Read Commands
The command is sent from PC to the projector with
the format below;
“CR” [Command] [CR]
Command: one character (refer to the command
table below.)
The projector decodes the command and returns the
'Character string' with the format below;
Format
Command Function Return
value Projector status
CR0 Status Read
00 Power On
80 Stand-by mode
40 Countdown
20 Cooling down
10 Power Malfunction
28 Cooling down at the temperature anomaly
24 Cooling down at Power Management mode
04 Power Management mode after Cooling down
21 Cooling down after the projector is turned off when the lamps
are out.
81 Stand-by mode after Cooling down when the lamps are out.
88 Stand-by mode after Cooling down at the temperature
anomaly.
2C Cooling down when the projector is turned off by the shutter
management function.
8C Stand-by mode after Cooling down by the shutter
management function.
CR6 Temperature Read %1 %2
%1 = Temperature at Sensor 1 (˚C)
%2 = Temperature at Sensor 2 (˚C)
(ex.) %1 = 12.3 (˚C), %2 = 23.4 (˚C)
--> The projector returns “ 12.3 23.4”.
( For each sensor, two digit and the tenth place numbers are
displayed with a space between each temperature.)
?Communication failure
The tables on page 97 and 98 show the typical command lists for controlling the projector. Please consult your
local dealer for further information of other commands.