Diagnostics

 

 

Interpreting Statistics

Statistic

Description

 

 

Ethernet

 

 

 

Link Status

A status string that represents the speed and

 

duplex setting being used to communicate with

 

the linking partner.

 

 

Frames Transmitted OK

A counter that increments each time a frame is

 

successfully transmitted.

 

 

Collisions

A counter that increments each time a frame is

 

retransmitted due to collision detection.

 

 

Excessive Collisions

A counter that increments each time a frame is

 

not able to be sent due to reaching the

 

maximum collision status based on the

 

Truncated Binary Exponential Backoff

 

algorithm.

 

 

Frames Received OK

A counter that increments each time a frame is

 

successfully received.

 

 

CRC Errors

A counter that increments each time a frame is

 

received that has a checksum/CRC that does

 

not match what is calculated.

 

 

Alignment Errors

A counter that increments each time a frame is

 

received that has a checksum/CRC error and

 

does not end on an 8-bit frame boundary.

 

 

Frames Too Long

A counter that increments each time a frame is

 

received that is larger than the allowed

 

maximum size defined in the standards (frames

 

larger than 1518 bytes).

 

 

Frames Too Short

A counter that increments each time a frame is

 

received that is smaller than the allowed

 

minimum size defined in the standards (frames

 

smaller than 64 bytes).

 

 

Modbus TCP/IP

 

 

 

Frames Sent

A counter that increments each time a frame is

 

sent.

 

 

Frames Received

A counter that increments each time a frame is

 

received.

 

 

Protocol Errors

A counter that increments each time an

 

ill-formed message is received.

 

 

Active Connectionsc

A status value that represents the number of

 

connections that are active at the moment the

 

diagnostics page is refreshed. A maximum of

 

32 connections are supported. Clicking Active

 

Connections opens a new window with a list of

 

all of the active client connections.

 

 

Accumulative Connectionsc

A counter that increments each time a

 

connection is made to the ETG.

 

 

Maximum Connectionsc

A status value that represents the maximum

 

number of connections that were active at any

 

given moment.

 

 

Inbound Read Messagesc

A counter that increments each time a read

 

request message is received.

 

 

Outbound Read Messagesd

A counter that increments each time a read

 

request message is sent.

 

 

Inbound Write Messagesc

A counter that increments each time a write

 

request message is received.

 

 

Outbound Write Messagesd

A counter that increments each time a write

 

request message is sent.

 

 

Inbound Reply Messagesd

A counter that increments each time a reply

 

message is received.

 

 

Outbound Reply Messagesc

A counter that increments each time a reply

 

message is sent.

 

 

cAvailable when the serial port is in Master mode.

dAvailable when the serial port is in Slave mode

ENGLISH

© 2006 Schneider Electric. All Rights Reserved.

15