11. Express Defrost Setting

NOTES:

1.Only Dual Digit Input method can be used when inputting memory numbers in Multiplication Factor for Double/Triple Quantity.

2.The multiplication factors can be set from 0.01 to 9.99 for double quantity and triple quantity.

3.When you want to know the multiplication factor for triple quantity, press the DOUBLE/TRIPLE QUANTITY twice at step 1 after pressing the CUSTOM SETTING pad twice.

4.Multiplication Factors for Double/Triple Quantity can be checked or changed before pressing the STOP/CLEAR pad to exit for Custom Setting Function.

11. Express Defrost Setting

*Suppose you want to change the Express Defrost set factory settings to the following:

 

Defrosting Time

 

Power Level

 

 

 

 

STAGE 1

T x 0.30 + 10 sec.

 

50%

 

 

 

 

STAGE 2

T x 0.15 + 20 sec.

 

20%

 

 

 

 

STAGE 3

T - STAGE1 - STAGE2

 

10%

 

 

 

Pause

When 70% of total defrosting time has

Timing

passed.

 

 

 

 

 

 

Procedure

Display

Express Defrosting uses 3 stages to defrost foods quickly. The defrosting sequence is preset as follows, but you can change the setting.

 

Defrosting Time

Power Level

 

 

 

STAGE

T x A1: (0.20*) + B1: (20*) sec.

PL1 (40*) %

1

 

 

 

 

 

STAGE

T x A2: (0.13*) + B2: (30*) sec.

PL2 (30*) %

2

 

 

 

 

 

STAGE

T - STAGE1 - STAGE2

PL3 (20*) %

3

 

 

 

 

 

Pause

See the table for The Pause

 

Timing

Timing below (50*)

 

 

 

 

T : INPUT TIME (TOTAL COOKING TIME)

Pause Timingx 2 Manual background

1Press the CUSTOM SETTING pad twice within 2 seconds and press the EXPRESS DEFROST pad.

(The Express Defrost setting of each phase is shown for 1.5 seconds at 0.3 second intervals until the MANUAL/REPEAT pad is pressed.)

(STAGE 1)

DEF.

CHECK

(A1)

 

DEF.

CHECK

(B1)

DEF. CHECK

(Power Level 1)

DEF. CHECK

(B2)

 

 

 

 

 

 

DEF.

CHECK

 

 

 

 

 

 

(Power Level 2)

DEF. CHECK

(STAGE 3)

DEF. CHECK

(Pause Timing)

DEF.

CHECK

*: The numbers in the parentheses are factory settings and can be adjusted.

Express Defrost is preset to pause during the sequence when 50% of total defrosting time has passed to check food. Pause timings can also be adjusted.

Pause Timing

KEY

Display

Pause Timing

 

 

 

0

0

No pause.

 

 

 

1

1

After 10% of total cooking time.

 

 

 

2

2

After 20% of total cooking time.

 

 

 

3

3

After 30% of total cooking time.

 

 

 

4

4

After 40% of total cooking time.

 

 

 

5

5

After 50% of total cooking time.

 

 

 

6

6

After 60% of total cooking time.

 

 

 

7

7

After 70% of total cooking time.

 

 

 

8

8

After 80% of total cooking time.

 

 

 

9

9

After 90% of total cooking time.

 

 

 

START

A

After ending of each stage

 

 

 

 

 

(STAGE 2)

 

 

(Power Level 3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DEF.

CHECK

 

 

 

DEF. CHECK

 

 

(A2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DEF.

CHECK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Press the MANUAL/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REPEAT pad and enter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

desired multiplication for

 

 

 

 

 

DEF.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A1 at Stage 1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

(Ex: Enter 3,0 for 0.30.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DEF.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DEF.

3

Press the MANUAL/REPEAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pad and enter desired time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for B1 at Stage 1.

 

 

 

 

 

DEF.

 

(Ex: Enter 1 for 10 seconds.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

4

Press the POWER LEVEL

 

 

 

 

 

DEF.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pad and enter desired

 

 

 

 

 

 

 

 

 

 

 

 

 

 

power level for PL1 at

 

 

 

 

 

 

DEF.

 

Stage 1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Ex: Enter 5 for 50%)

5

 

 

 

 

 

 

 

 

 

 

DEF.

16

Page 17
Image 17