1.Remove all packing materials. Remove the protective film (blue film) from the outer case cabinet (if covered).

2.Place oven on a secure, level surface, strong enough to take the oven weight, plus the heaviest item likely to be cooked in the oven.

3.Ensure there is a minimum free space above the oven of 25 cm.

4.Do not place the oven where heat, moisture or high humidity are generated, (for example, near or above a conventional oven) or near combustible materials (for example, curtains). Do not block or obstruct air vent openings, as obstructions may ignite due to the emission of hot air.

5.Make sure the power supply cord is undamaged (See Installation next page) and that it does not run under the oven or over any hot or sharp surfaces.

6.The socket must be readily accessible so that it can be easily unplugged in an emergency.

7.Do not use the oven outdoors.

8.Two same oven models can be installed together by placing one on top of another. Follow these instructions.

A.Place oven A in the desired location. Position Oven B on top of Oven A as shown in the figure.

B.Remove Screws (a) and Mounting plate A and B from the right side of the back of Oven A and B.

C.Replace Screws (a) removed at step B and tighten them.

D.Remove Screws (b), (c), (d), and (e) and then install Mounting Plate A and B which were removed at step B to the each lower edge of Oven B as shown in the figure.

E.Replace Screws (b), (c), (d), and (e) which were removed at step D and tighten them.

IMPORTANT! ELECTRICAL CONNECTION Screw (a)

Oven B (Back)

Mounting plate B

Screw (e)

Screw (b)

 

Screw (b)

Screw (e)

Screw (d)

Screw (c)

Screw (c)

 

 

Screw (d)

Oven A (Back)

 

Screw (a)

 

Mounting

 

 

 

 

 

 

 

 

plate A

THIS APPLIANCE MUST BE EARTHED. WARNING:

In situations where two ovens are installed together by placing one on top of another,

1)Use the two mounting plates for fixing the two ovens.

2)Make sure that the power supply cord is not caught between the two ovens.

3)Do not install more than one oven on top of another.

4)Do not lose the removed screws.

NOTE: External Equipotential Earthing Terminal

Equipment has secondary earthing terminal. Terminal provides external earthing connection used in addition to earthing prong on plug. Located on outside of oven back, terminal is marked with symbol shown on the right side.

Radio or TV Interference WARNING:

It is hazardous for anyone other than a Service Technician, approved by SHARP to carry out any service or repair operation which involves the removal of a cover which gives protection against exposure to microwave energy.

IMPORTANT! ELECTRICAL CONNECTION

Do not allow water to come into contact with the power supply cord or plug.

Insert the plug properly into the socket as the plug may otherwise overheat and catch fire.

Do not connect other appliances to the same socket using an adaptor plug as it may cause the wiring to overheat and catch fire.

If the plug or socket is loose or the power supply cord is damaged, do not operate the oven, it must be replaced by the special power cord. Contact your dealer or a Service Technician appointed by SHARP.

A defective plug, power supply cord or socket may overheat and catch fire during operation or cause an electrical shock.

When removing the plug from the socket always grip the plug, never the mains lead as this may damage the power supply cord and the connections inside the plug.

The product is fitted with a non-rewireable (moulded) plug. Should it not be suitable for the socket outlet in your kitchen, remove the plug and fit an appropriate type, observing the wiring code given in “To replace the mains plug” on page 39.

The fuse from a cut-off plug should be removed and the plug disposed of in safe manner. Under no circumstances should the cut-off plug be inserted into a socket outlet as serious electrical shock may occur. The plug must not be used without the fuse cover fitted.

When replacing the plug please ensure that you use a BSI or ASTA approved plug to BS1363, this should be fitted with a brown coloured 13 amp fuse approved by BSI or ASTA to BS1362. If you have any doubt about electrical connection seek the help of a qualified electrician.

Manual background WARNING:

THIS APPLIANCE MUST BE EARTHED.

To wire an appropriate plug, follow the wiring code given in “To replace the mains plug” on page 39.

Radio or TV Interference

Should there be any interference caused by the microwave oven to your radio or TV, check that the microwave oven is on a different electrical circuit, relocate the radio or TV as far away from the oven as feasible or check position and signal of receiving antenna.

3

Page 4
Image 4
Sharp R-1900M I Nstallation, NOTE External Equipotential Earthing Terminal, Important! Electrical Connection