Problem

Check

Page

 

 

 

 

 

The cooling fan

When temperature inside the projector increases, the cooling fan runs

 

becomes noisy.

faster.

 

 

 

 

 

 

The lamp does not light up

The lamp indicator is illuminating in red.

23, 60, 63

 

even after the

Replace the lamp.

 

 

projector turns on.

 

 

• The lens shutter is opened fully.

 

 

 

 

 

The lamp suddenly turns off

 

 

 

 

 

during projection.

 

 

 

 

 

 

 

The image sometimes

Cables are incorrectly connected to the projector or the connected equip-

19-22

 

flickers.

ment works improperly.

 

 

 

If this happens frequently, replace the lamp.

63

 

 

 

 

 

The lamp needs much time

The lamp will eventually need to be changed.

63

 

to turn on.

While the remaining lamp life draws to a close, replace the lamp.

 

 

 

 

 

 

Picture is dark.

 

 

 

 

 

 

 

One Touch Play is not

Non-Sharp Video Products are connected.

46

 

enabled.

One Touch Play function may not work when the projector is connected

 

 

 

to non-Sharp Video Products.

 

 

 

 

 

 

 

An HDMI cable is not used for connection between the projector and the

20

 

 

Sharp Video Products.

 

 

 

One Touch Play function is enabled when the projector is connected to

 

 

 

the Sharp Video Products with an HDMI cable.

 

 

 

 

 

 

 

One Touch Play function of the projector is not set to “On”.

46

 

 

 

 

 

 

CEC settings of connected Sharp Video Products or other CEC devices

 

 

are incorrect.

 

 

 

 

 

 

 

One Touch Play is set to “Off” and disabled when the Economy mode is

46

 

 

set to “On”.

 

 

 

 

 

 

System Standby is not

Non-Sharp Video Products are connected.

46

 

enabled.

System Standby function may not work when the projector is connected

 

 

 

to non-Sharp Video Products.

 

 

 

 

 

 

 

An HDMI cable is not used for connection between the projector and the

20

 

 

Sharp Video Products.

 

 

 

System Standby function is enabled when the projector is connected to

 

 

 

the Sharp Video Products with an HDMI cable.

 

 

 

 

 

 

 

System Standby function of the projector is not set to “On”.

46

 

 

 

 

 

 

CEC settings of connected Sharp Video Products or other CEC devices

 

 

are incorrect.

 

 

 

 

 

 

A response code cannot be

In the case of transmitting RS-232C commands from a computer during

66

 

received when the

standby, it takes a maximum of 30 seconds for the computer to receive

 

 

projector was attempted

the response code. Set the response code waiting time of the computer

 

 

to be controlled using

to 30 seconds or more.

 

 

RS-232C commands from

 

 

 

a computer during standby.

 

 

 

 

 

 

 

The remote control

Operate the remote control while pointing it at the projector’s remote

13

 

cannot be used.

control sensor.

 

 

 

The remote control may be too far away from the projector.

13

 

 

If direct sunlight or a strong fluorescent light is shining on the projector’s

13

 

 

remote control sensor, place the projector where it will not be affected by

 

 

 

strong light.

 

 

 

 

 

 

 

The batteries may be depleted or inserted incorrectly. Make sure the bat-

13

Appendix

 

teries are inserted correctly or insert new ones.

 

 

 

 

 

 

 

 

-73

Page 75
Image 75
Sharp XV-Z17000 operation manual Replace the lamp