1.1.6.1 Remote-SAT State Transition Diagram

POWER ON (Hardware Reset)

RESET

/0

OFF

/1

"AT^SSTR=<PAC>,<status>,... E

"OK"IDLE "^SSTN:254" (an optional URC,

if SIM Application has /2 returned to its main menu)

WAIT

/4

D"AT^SSTGI=<PAC>" "^SSTGI:<PAC>,..."

Output depends on PAC "OK"

Event : SIM sends first Proactive

ACommand

B"AT^SSTA=1,x"

"OK"

F"AT^SSTR=<2xx>,..."

"OK"

SIM sends PAC

C ^SSTN:<PAC>" (URC)

PAC

/3

GSIM terminates PAC

"^SSTN:<PAC>" (as URC)