Siemens MC35 manual Proactive Commands Atsstr Remote-SAT Response Refresh, ATSSTR=1, ATSSTR=5

Models: MC35

1 65
Download 65 pages 56.08 Kb
Page 43
Image 43

Remote-SAT User's Guide

1.5.2Proactive Commands

1.5.2.1AT^SSTR Remote-SAT Response – Refresh (1)

Write command

AT^SSTR=1,

<status>

If <cmdDetail> reported by AT^SSTGI was 4, ME is performing a SIM reset. Therefore a Terminal Response should not be issued.

Response

OK

Parameters

<cmdType> 1 – Proactive command ID, see Table 1

<status> Unsigned Integer, range 0-255

0

Command performed successfully

32

TA currently unable to process command

132TA currently unable to process command because screen is busy.

ReferenceNote

Siemens

1.5.2.2 AT^SSTR Remote-SAT Response – Set Up Event List (5)

Write command

AT^SSTR=5,

<status>

Reference

Siemens

The TA is acknowledging that the Event list has been set up correctly.

Response

OK

Parameters

<cmdType> 5 – Proactive command ID, see Table 1

<status> Unsigned Integer, range 0-255

0

Command performed successfully

32

TA currently unable to process command

132TA currently unable to process command because screen is busy.

Note

MC35_SAT_01_v02.00

Page 43 of 65

11.01.2002

Page 43
Image 43
Siemens MC35 Proactive Commands Atsstr Remote-SAT Response Refresh, Atsstr Remote-SAT Response Set Up Event List, ATSSTR=1