Simrad SIMRAD HS50 manual Cable, Interface, Processing unit to sensor unit cable

Models: SIMRAD HS50

1 63
Download 63 pages 5.61 Kb
Page 16
Image 16

Simrad HS50 Heading Sensor

Processing unit

Enclosure material:

Anodized aluminum

Enclosure protection:

IP44

Operating temperature range:

0 to +55ºC (32 to 131°F)

Storage temperature range:

-20 to +60ºC (-4 to 140°F)

Safe distance to compass:

0.2 m (0.7 ft)

2.8 Cable

 

Processing unit to sensor unit cable

Type:

2x2x0.5 mm2 with shield

Maximum length:

100 m (328 ft)

Diameter:

10 mm (0.4 in.)

Flame retardation:

IEC 332-3/A

2.9 Interface

Configuration:

Display unit connected to the Processing unit

Data outputs:

Three RS-232 serial lines,

 

Three RS-422 serial lines,

 

 

Ethernet UDP/IP

Data inputs:

One RS-232 and one RS-422 serial line

DGPS corrections:

RTCM 104 version 2.2 and SAPOS® EPS

Baud rate:

Max. 38.4 kBaud

HDT, ROT, GGA and GLL data update rates:

.......... Up to 20 Hz

HDT, ROT, GGA and GLL data delay:

Less than 50 ms

ZDA and VTG data update rate:

Max 1 Hz

VTG data delay:

Max 1.5 sec

ZDA data delay:

1 ms

Data output formats:

NMEA 0183 ZDA, GGA, GLL, VTG, HDT, ROT, GSA, GRS and proprietary messages PSXN,20. The PSXN,20 message include position, height and heading quality information

RD Instrument ADCP proprietary NMEA format, "PRDID".

Radar clock data