Simrad SIMRAD HS50 manual Ethernet, General

Models: SIMRAD HS50

1 63
Download 63 pages 5.61 Kb
Page 36
Image 36

Simrad HS50 Heading Sensor

Ethernet

The Processing unit can output data on Ethernet from terminal J60. In the Ethernet submenu the IP address, netmask, IP port number and output format have to be specified. For the NMEA format the messages GGA, GLL, VTG, HDT, ROT and RRE are included.

 

IP Address:

Default setting: 010 000 021 030.

 

IP Netmast:

Default setting: 255 255 255 000.

 

Format:

Format on Ethernet line. The following

 

 

selections are available: NMEA and None.

WARNING!

If “None” is selected as output format, no data will be

 

sent to Ethernet line.

Caution! A change in IP Address and IP Netmask parameter will not

take effect before the HS50 is restarted!

Note!

The cable to be used has to be a crossed Ethernet cable.

General

The General submenu includes selection of height aiding, velocity filtering, Clock data, NMEA id and Datum.

28

20221081 / F

Page 36
Image 36
Simrad SIMRAD HS50 manual Ethernet, General