INSTALLATION

 

Data output

 

The Processing unit has two individually configurable output

 

serial lines.

 

On output line Data output 1 two RS-232 and two 422 serial

 

lines are available. The signal cables can be connected to both

 

terminal block P202 and P203.

 

On Data output 2 one RS-232 and one 422 serial lines are

 

available. The signal cables are to be connected to terminal

 

block P204.

Note!

All six serial lines may be used simultaneously!

 

The setup of baud rate, interval between NMEA sentences and

 

output formats for each port are performed in the Data output 1

 

and Data output 2 submenu.

 

 

 

 

 

 

 

 

 

Baudrate:

The rate at which bits are transmitted. 4800 is

 

 

standard NMEA rate.

 

 

Interval:

Interval in seconds between

each NMEA

 

 

sentence.

 

 

 

Example:

 

 

 

 

 

 

 

 

Interval setting

 

Hz

 

 

 

 

 

 

 

1 sec

 

1 Hz

 

 

 

 

 

 

 

0.5 sec

 

2 Hz

 

 

 

 

 

 

 

0.2 sec

 

5 Hz

 

 

 

 

 

 

 

0.1 sec

 

10 Hz

 

 

 

 

 

 

 

0.05 sec

 

20 Hz

 

Format:

 

 

 

Format on data output line. The following

 

 

selections are available: NMEA and none.

 

NMEA Format: NMEA sentences to be sent to output line.

WARNING!

If “none” is selected as output format, no data will be

 

sent to output line.

 