If the Sensor unit connector needs to be reconnected to the cable, the wiring for the cable within the Sensor unit connector is as follows:

 

 

Sensor Unit

Cable Wire No.

Signal Description

 

 

Connector

 

 

 

 

 

 

Pin no.

 

 

1

4

Connector housing

Screen

Shield

 

 

 

 

2

4

Transmit

2

3

4

3

Receive

FRONT VIEW

 

3

2

+24 VDC

 

 

1

1

Power ground

Waterproofing the connectors

The Sensor unit connector junction has to be sealed with self- bonding tape and PVC/Vinyl tape for waterproofing.

1Coil the self-bounding tape from one cable end to the other. Use at least two layers with tape. After coiling, make a bonding by pressure of fingers.

2Coil at least two layers of PVC/Vinyl tape without stretching as shown in the figure below. After coiling, make a bonding by pressure of fingers.

3.5Display unit

Location of the unit

Avoid mounting the Display unit where it is easily exposed to sunlight, as this will shorten the lifetime of the display. If this is not possible, make sure the unit is always covered with the white protection cover when not used.

The unit is designed for installation in an indoor environment and for operation within the temperature range. The best location is typically in the instrument room or on the bridge mounted close to the Processing unit.