OPERATING INSTRUCTIONS

Number of satellites used in the GPS position solution and the number of satellites tracked by GPS antenna no. 1 (Tr1) and 2 (Tr2).

This display is mainly used by service personnel.

Software version for each unit (Distribution Unit = DU, Sensor Unit = SU and Processing Unit = PU), together with internal serial number for Sensor and Processing unit. The date behind each unit’s software version refers to manufacture date for the unit.

System load as percentage of used CPU capacity.

4.4Alarms

The HS50 will generate an acoustic alarm and an alarm text if heading or position information is invalid or missing.

The acoustic alarm will sound for 5 seconds, and the alarm text will remain in the display until the NAV1 or NAV2 button is pressed. No data will be output from HS50 as long as the alarm situation is present.

If the SETUP menu is active when the alarm condition arises, the alarm text will be displayed when the SETUP menu is left.

Note!No alarm will be activated if the system is setup to not respond to alarm situations. Refer Expert setup, page 30.

20221081 / F