.1/9.3)

CWT7 Cadence

Cadence script for distinctive CWT 7

30(.1/.1, .3/.1,

 

 

.1/9.3)

CWT8 Cadence

Cadence script for distinctive CWT 8

2.3(..3/2)

Ring1 Name

Name in an INVITE’s Alert-Info Header to pick distinctive

Bellcore-r1

 

ring/CWT 1 for the inbound call

 

Ring2 Name

Name in an INVITE’s Alert-Info Header to pick distinctive

Bellcore-r2

 

ring/CWT 2 for the inbound call

 

Ring3 Name

Name in an INVITE’s Alert-Info Header to pick distinctive

Bellcore-r3

 

ring/CWT 3 for the inbound call

 

Ring4 Name

Name in an INVITE’s Alert-Info Header to pick distinctive

Bellcore-r4

 

ring/CWT 4 for the inbound call

 

Ring5 Name

Name in an INVITE’s Alert-Info Header to pick distinctive

Bellcore-r5

 

ring/CWT 5 for the inbound call

 

Ring6 Name

Name in an INVITE’s Alert-Info Header to pick distinctive

Bellcore-r6

 

ring/CWT 6 for the inbound call

 

Ring7 Name

Name in an INVITE’s Alert-Info Header to pick distinctive

Bellcore-r7

 

ring/CWT 7 for the inbound call

 

Ring8 Name

Name in an INVITE’s Alert-Info Header to pick distinctive

Bellcore-r8

 

ring/CWT 8 for the inbound call

 

Ring Waveform

Waveform for the ringing signal

Sinusoid

Ring Frequency

Frequency of the ringing signal. Valid values are 10 – 100

25

 

(Hz)

 

Ring Voltage

Ringing voltage. 60-90 (V)

70

CWT Frequency

Frequency script of the call waiting tone. All distinctive

440@-10

 

CWT is based on this tone.

 

Notes:

 

 

3.4.7.3.Control Timer Values (sec)

Parameter Name

Description

Default

 

Hook Flash Timer Min

Minimum on-hook time before off-hook to qualify as hook-

0.1

 

 

flash. Less than this the on-hook event is ignored. Range: 0.1

 

 

 

– 0.4 sec

 

 

 

Hook Flash Timer Max

Maximum on-hook time before off-hook to qualify as hook-

0.9

 

 

flash. More than this the on-hook event is treated as on-hook

 

 

 

(no hook-flash event). Range: 0.4 – 1.6 sec

 

 

Callee On Hook Delay

The phone must be on-hook for at this time in sec before the

0

 

 

SPA will tear down the current inbound call. It does not apply

 

 

 

to outbound calls. Range: 0 – 255 sec

 

 

Reorder Delay

Delay after far end hangs up before reorder tone is played. 0 =

5

 

 

plays immediately, inf = never plays. Range: 0 – 255 sec

 

 

Call Back Expires

Expiration time in sec of a call back activation. Ragne: 0 –

1800

 

 

65535 sec

 

 

Call Back Retry Intvl

Call back retry interval in sec. Range: 0 – 255 sec

30

 

Call Back Delay

Delay after receiving the first SIP 18x response before

0.5

 

 

declaring the remote end is ringing. If a busy response is

 

 

 

received during this time, the SPA still considers the call as

 

 

 

failed and keeps on retrying.

 

 

VMWI Refresh Intvl

Interval between VMWI refresh to the CPE

0.5

 

Interdigit Long Timer3

Long timeout between entering digits when dialing. Range: 0 –

10

 

 

64 sec

 

 

 

 

 

 

 

 

© 2003 Sipura Technology, Inc