“CONFIGURE” Allows the individual options such as counterbalance, cushion, and slide adjust modules to be configured during initial installation of the system and will not be used for production operation setup. Note that this key is only available when the RUN/PROG keyed switch is in the PROG position.

“JOG UP”Press this softkey to move the slide up. A momentary push will “pulse” the slide up once for fine control. If the key is held down for more than about ½ a second, the slide will move up continuously until the key is released. This key is only available when the keyed slide adjust switch is in the ON position and the editing cursor is on the slide setpoint.

“JOG DOWN”Press this softkey to move the slide down. A momentary push will “pulse” the slide down once for fine control. If the key is held down for more than about ½ a second, the slide will move down continuously until the key is released. This key is only available when the keyed slide adjust switch is in the ON position and the editing cursor is on the slide setpoint.

“AUTO ADJUST” Press this softkey to automatically move the slide to the setpoint. An auto adjust sequence always goes above the setpoint and then comes down to it for consistency. This key is only available when the keyed slide adjust switch is in the ON position and the editing cursor is on the slide setpoint. Note that when an auto adjust sequence is in progress, this key will change to “CANCEL AUTO ADJUST”. When pressed under this circumstance, it will cancel the auto adjust sequence and cause slide motion to stop.

“RESET ERROR” Certain errors will cause the auto setup module to generate a top stop or cycle stop to the press. When this occurs, the “RESET ERROR” softkey will appear. Before the press can be started again, the fault must be corrected and this key must be pressed to clear the error condition. Note that this is a restricted operation and an access code may be required depending on system configuration as detailed in section 2.

Section 5.1 Slide Adjust Operation

Each configured slide system has its own “box” on the screen (Figure 5.1 shows a setup with only one slide adjust system). The title of the box has the shut height system name and the mode the system is in (ON, OFF, or MANUAL). This box contains:

Setpoint

The desired position of the slide shut height adjustment. This number may be

 

changed by manual operator entry when the operator has access via key or user

 

code depending on the configuration of the system as detailed in section 2. The

 

setpoint will also be changed to the required slide setpoint for a previously stored

 

job when that job setup is recalled from memory and the system is ON. The units

 

for this setpoint can be in inches or millimeters depending on the configuration.

 

See section 4.2.2 for details.

Actual Position

The actual position of the slide shut height adjustment as indicated by a linear or

April 17, 2000 Man ual Versio n 1.0