SMC Networks 5000 manual Configuring Slide Adjust Modules

Models: 5000

1 80
Download 80 pages 31.64 Kb
Page 31
Image 31

Table 4.2: Servo-Valve Control Types

 

Wilkerson ER1 Series

0-90psi

0-10V

5

SMC ITV2050-31T2S4

0-130psi

0-10V

6

Section 4.2.2 Configuring Slide Adjust Modules

 

 

To get to the configuration screen for slide adjust

modules:

 

 

a)Go to the “Auto Sets” screen. This screen is reached by pressing the “AUTO SETS” softkey in the Main Menu or Press Control screen.

b)With the RUN/PROG key switch in the PROG position, press the “CONFIGURE” softkey and enter the configuration code. The code is provided separately from this manual for administrative control.

c)Press the “CONFIGURE SLIDE”softkey.

d)Turn the Slide Adjust OFF/ON selector switch for your control to the ON position.

At this point the screen should look similar to Figure 3.3.

Figure 4.3: Example Slide Configuration Screen

There are several parameters that must be configured in this screen. The editing cursor indicates which

April 17, 2000 Man ual Versio n 1.0

4.7

Page 31
Image 31
SMC Networks 5000 manual Configuring Slide Adjust Modules