SMC Networks 5000 Fault, Status, Slide On, Manual, and Off Settings, MAN manual

Models: 5000

1 80
Download 80 pages 31.64 Kb
Page 42
Image 42

 

rotary transducer mounted on the slide system of the press. The units for the

 

position can be in inches or millimeters depending on the configuration. See

 

section 4.2.2 for details.

Fault

If the slide adjust system detects an error it will be reported on this line. A fault

 

occurs when a hardware or firmware problem is diagnosed by the system. See

 

section 6 for fault messages and their meanings.

Status

The current status of the slide adjust system. Status messages indicate what the

 

system is doing in the normal course of its operation. See section 6 for status

 

messages and their meanings.

Section 5.1.1 Slide On, Manual, and Off Settings

The Auto-Setup module allows three modes of operation to be chosen in the configuration menu for each slide adjust system - “ON”, “MAN” (manual), or “OFF”. ON is the proper mode for the normal intended use of the system.

The operator or setup person cannot change the mode in the operation screen but the setting is reported at the top of the slide adjust box after the slide name (“Slide Adjust #1" or “Slide Adjust #2") for convenience.

The mode setting affects the operation of the slide system in the following ways:

“ON”

Jobs that are recalled will automatically move the slide to the position stored in

 

the job subject to the conditions described in section 5.1.2. The “AUTO

 

ADJUST” softkey can be used to initiate automatic movement of the slide to the

 

currently programmed setpoint. The “JOG UP” and “JOG DN” softkeys can be

 

used to manually move the slide.

“MAN” (manual)

This mode can be chosen if there is some reason the employer does not want to

 

allow recall of previously stored job setups from memory. The slide position will

 

not automatically change when a job is recalled. The slide setpoint can still be

 

changed by manual entry of the desired setpoint and by pressing the “AUTO

 

ADJUST” softkey to initiate an auto adjust sequence. The “JOG UP” and “JOG

 

DN” softkeys can be used to manually move the slide.

“OFF”

The slide position will not automatically change when a job is recalled. No

 

automatic movement will occur even if the “AUTO ADJUST” softkey is pressed.

 

The “JOG UP” and “JOG DN” softkeys will still move the slide. This mode is

 

provided to allow temporary reversion to completely manual adjustment of shut

 

height by use of the “JOG UP” and “JOG DN” softkeys if the slide mounted

 

transducer fails.

Section 5.1.2 Automatic Slide Movement

Automatic movement of the slide can be initiated by either pressing the “AUTO ADJUST” softkey in

April 17, 2000 Man ual Versio n 1.0

5.4

Page 42
Image 42
SMC Networks 5000 Fault, Status, Slide On, Manual, and Off Settings, MAN manual, Automatic Slide Movement