![](/images/new-backgrounds/1188845/18884583x1.webp)
| rotary transducer mounted on the slide system of the press. The units for the |
| position can be in inches or millimeters depending on the configuration. See |
| section 4.2.2 for details. |
Fault | If the slide adjust system detects an error it will be reported on this line. A fault |
| occurs when a hardware or firmware problem is diagnosed by the system. See |
| section 6 for fault messages and their meanings. |
Status | The current status of the slide adjust system. Status messages indicate what the |
| system is doing in the normal course of its operation. See section 6 for status |
| messages and their meanings. |
Section 5.1.1 Slide On, Manual, and Off Settings
The
The operator or setup person cannot change the mode in the operation screen but the setting is reported at the top of the slide adjust box after the slide name (“Slide Adjust #1" or “Slide Adjust #2") for convenience.
The mode setting affects the operation of the slide system in the following ways:
“ON” | Jobs that are recalled will automatically move the slide to the position stored in |
| the job subject to the conditions described in section 5.1.2. The “AUTO |
| ADJUST” softkey can be used to initiate automatic movement of the slide to the |
| currently programmed setpoint. The “JOG UP” and “JOG DN” softkeys can be |
| used to manually move the slide. |
“MAN” (manual) | This mode can be chosen if there is some reason the employer does not want to |
| allow recall of previously stored job setups from memory. The slide position will |
| not automatically change when a job is recalled. The slide setpoint can still be |
| changed by manual entry of the desired setpoint and by pressing the “AUTO |
| ADJUST” softkey to initiate an auto adjust sequence. The “JOG UP” and “JOG |
| DN” softkeys can be used to manually move the slide. |
“OFF” | The slide position will not automatically change when a job is recalled. No |
| automatic movement will occur even if the “AUTO ADJUST” softkey is pressed. |
| The “JOG UP” and “JOG DN” softkeys will still move the slide. This mode is |
| provided to allow temporary reversion to completely manual adjustment of shut |
| height by use of the “JOG UP” and “JOG DN” softkeys if the slide mounted |
| transducer fails. |
Section 5.1.2 Automatic Slide Movement
Automatic movement of the slide can be initiated by either pressing the “AUTO ADJUST” softkey in
April 17, 2000 Man ual Versio n 1.0 | 5.4 |