Min Position Reached

The slide has gone as low as the min position programmed in the

 

configuration menu and will not be allowed to go lower.

Moving Up

The slide is moving up.

Moving Down

The slide is moving down.

System Off

The slide adjust system is turned off. The slide can still be manually moved

 

by using the jog up and jog down buttons. The slide position will still be

 

shown if the position transducer is still functioning correctly.

Waiting for Cntr-Bal

The slide adjust system is waiting for the counterbalance, if present, to come

 

to its correct pressure before automatically moving the slide.

Slide Too High

The slide is higher than the slide setpoint plus tolerance.

Slide Too Low

The slide is lower than the slide setpoint minus tolerance.

Hyd Overload Tripped

The hydraulic overload has tripped. The slide will not move down in this

 

condition.

Auto-Adjusting

The slide is automatically going to the programmed slide setpoint.

Waiting for Top

The slide must be at the top of the stroke for automatic positioning to occur.

 

If a job is recalled at the bottom of the stroke, this message will be displayed

 

until the press is at the top.

E-Stop Button

Emergency stop button is depressed. The slide will not automatically move in

 

this condition.

Waiting S/A Switch

Waiting for the slide adjust switch to be turned on. The slide cannot move

 

while the slide adjust switch is in the off position.

LMC is Out

The Link Master Control relay is disengaged for some reason (possibly an

 

error at the control). No slide movement may be made while the LMC is

 

tripped.