For cushions this should be the maximum operating pressure specified by the

 

cushion manufacturer.

 

For hydraulic overloads this value should be the pressure specified by the press

 

manufacturer for rated tonnage operation.

Min. Pressure

This value should be set to the minimum operating pressure at which you will

 

operate your counterbalance, cushion, or hydraulic overload.

 

For counterbalances, this value is the pressure that balances the slide with no

 

tooling and cannot be set below 5 psi. Obtain this value from the press

 

counterbalance table or press manual.

 

For cushion(s), the Min. Pressure should be set to at least the value that just barely

 

supports the weight of the cushion cylinder. This can be found by slowly

 

increasing the pressure to the cushion until it just starts to rise. Then back off the

 

pressure until it just starts to fall. The Min. Pressure should be set to at least the

 

average of the two pressures. The Type “B” and “C” valve systems may be used

 

to provide a minimum pressure through their manual regulator. This keeps the

 

cushion from falling due to air leakage when the control is powered off and

 

prevents cushion pins from falling through the lower die shoe and bolster.

 

NOTE! Cushions can always drift down when the plant air supply is off.

 

Also, If a type “B” valve is used, Min Pressure must be set above the manual

 

regulator setting.

 

For hydraulic overloads, the Min. Pressure should generally not be set to less than

 

25% of the Max. Pressure value.

Max. Die Weight

This parameter only appears when a counter balance is being configured.

 

This should be set at the die weight the counterbalance handles at its maximum

 

pressure. Obtain this value from the press counterbalance table or press manual.

 

Note that the units to the right of this parameter are also configurable. When the

 

editing cursor is placed on these units, softkey 1 will read “CHANGE UNIT”.

 

When pressed, pounds, kilograms, tons, or metric tons may be selected from a list.

 

Note that changing the unit here will also change the unit for Min. Die Weight.

Min. Die Weight

This parameter only appears when a counter balance is being configured.

 

Set this value to 0 die weight. (This represents no tooling on the upper slide at the

 

minimum counterbalance pressure). Note that the units to the right of this

 

parameter are also configurable. When the editing cursor is placed on these units,

 

softkey 1 will read “CHANGE UNIT”. When pressed, pounds, kilograms, tons,

 

or metric tons may be selected from a list. Note that changing the unit here will

 

also change the unit for Max. Die Weight.

Display Weight As

This parameter only appears when a counter balance is being configured.

 

Set this parameter to the units that die weight should be displayed in. The choices