SMC Networks 5000 manual Calibrating Rotary Slide Adjust Systems, Or death

Models: 5000

1 80
Download 80 pages 31.64 Kb
Page 35
Image 35

transducer is used) must now be set. This value is listed on the transducer model plate. Press the “CONTINUE SLIDE CAL.” softkey to continue the calibration process or “EXIT” to return to slide configuration.

f)Finally, the “Calibration Point” must be set. The slide should be taken to bottom dead center (180 degrees) and the shut height should be measured. Without moving the slide that measurement should be entered here. This tells the system what the current shut height is. Press the “CONTINUE SLIDE CAL.” softkey.

g)The slide system should now be calibrated. Check for proper operation by running the slide up near the top of the adjustment range and checking the slide position reported. Note that linear transducers are repeatable but not absolutely accurate. This means the reported slide position may differ from the measured position by as much as .030". Repeat this process with the slide near the bottom of the adjustment range.

WARNING: After calibration always check for proper operation of the slide adjust system as wiring or transducer faults could cause an invalid calibration. Bad measurements could result in damage to the machine and tooling, and can cause injury or death.

Section 4.2.2.2 Calibrating Rotary Slide Adjust Systems

After setting the parameters in the previous section, the rotary slide system must be calibrated before it can be used.

IMPORTANT! Configuring/calibrating the slide adjust module should only be done with no dies installed in the press and, for presses equipped with slide counterbalance systems, should proceed only after the counterbalance is properly adjusted to offset the weight of the slide. If counterbalance pressure is too low, bearing clearances will cause shut height measurements made during calibration to be too small.

WARNING!

Since the slide adjust configuration procedure requires measurement of

 

the space between the press slide and bed or bolster, this procedure must

 

be performed with no dies or tooling in the press to prevent the possibility

 

of a point of operation or pinch point injury to personnel making the

 

measurement. Failure to heed this warning may result in serious injury

 

or death.

To calibrate a rotary slide adjust system:

a) Make sure the upper and lower limit settings have been set correctly in the slide configuration

April 17, 2000 Man ual Versio n 1.0