parameter is currently selected. Softkey 1 (the uppermost vertical softkey) will change its description based on the parameter and, when pressed, allows the currently selected parameter to be changed. The up and down arrow keys move the editing cursor from one parameter to another. See Appendix A for examples of setting up each kind of system. The features of this screen are:

Help

The “Help” box at the bottom of the screen changes depending on the parameter

 

that the editing cursor is currently on. It gives a short version of how the

 

parameter is used.

Slide Slot

Corresponds to the physical slot number (SS1 in the example of Figure 4.3)

 

selected for configuration on the auto-setup card. The “NEXT SLIDE SLOT”

 

softkey will cycle between SS1 and SS2.

Hardware Detected

This will be “Linear Transducer” for 5000-10B option boards or “Rotary

 

Transducer for 5000-10C option boards. If there is no option board installed in

 

that slot this should read “None Detected”.

Shutheight

The current slide position reported by the transducer. NOTE! This number will be

 

incorrect until Cal. Position and Orientation are entered during configuration.

 

This is reported as a convenience in this screen cannot be changed by the user.

Name

Use the “CHANGE NAME” soft key repetitively to cycle through the available

 

names for this system (Slide Adjust #1, Slide Adjust #2, Not Configured). Stop

 

when the desired name appears. This name will appear on the Auto-Sets screen.

Mode

Use the “CHANGE MODE” soft key to cycle the status from ON to MAN to

 

OFF and back to ON. ON means the OmniLink 5000 automatically adjusts to the

 

new shut height associated with a job when that job is recalled from memory, but

 

only if the Slide Adjust OFF/ON selector switch is turned to the ON position.

 

MAN means the OmniLink 5000 can control the shut height but the shut height

 

can only be changed from the “Slide Adjust” screen. A RECALLED job will

 

NOT change the shut height, although an operator can cause the system to

 

automatically adjust to a new shut height by turning the Slide Adjust OFF/ON

 

switch to the ON position, entering the desired shut height value in the “Slide

 

Setpoint” row, and pressing the “AUTO ADJUST” softkey. OFF means the 5000

 

will not automatically adjust the shut height, and will ignore any errors from the

 

system. Operators can always manually jog the slide into position through the use

 

of the “JOG UP” and “JOG DOWN” softkeys. These keys appear when the Slide

 

Adjust OFF/ON switch is in the ON position regardless of whether ON, MAN, or

 

OFF is configured. This value should typically be set to ON.

Shut Height Units

All shutheight parameters and the shut height actual position can be displayed and

 

entered in inches or millimeters. Use the “CHANGE UNIT” softkey to toggle

 

this setting between inches and millimeters. Note that values already entered will

 

be converted to the new unit.