parameter is currently selected. Softkey 1 (the uppermost vertical softkey) will change its description based on the parameter and, when pressed, allows the currently selected parameter to be changed. The up and down arrow keys move the editing cursor from one parameter to another. See Appendix A for examples of setting up each kind of system. The features of this screen are:
Help | The “Help” box at the bottom of the screen changes depending on the parameter |
| that the editing cursor is currently on. It gives a short version of how the |
| parameter is used. |
Slide Slot | Corresponds to the physical slot number (SS1 in the example of Figure 4.3) |
| selected for configuration on the |
| softkey will cycle between SS1 and SS2. |
Hardware Detected | This will be “Linear Transducer” for |
| Transducer for |
| that slot this should read “None Detected”. |
Shutheight | The current slide position reported by the transducer. NOTE! This number will be |
| incorrect until Cal. Position and Orientation are entered during configuration. |
| This is reported as a convenience in this screen cannot be changed by the user. |
Name | Use the “CHANGE NAME” soft key repetitively to cycle through the available |
| names for this system (Slide Adjust #1, Slide Adjust #2, Not Configured). Stop |
| when the desired name appears. This name will appear on the |
Mode | Use the “CHANGE MODE” soft key to cycle the status from ON to MAN to |
| OFF and back to ON. ON means the OmniLink 5000 automatically adjusts to the |
| new shut height associated with a job when that job is recalled from memory, but |
| only if the Slide Adjust OFF/ON selector switch is turned to the ON position. |
| MAN means the OmniLink 5000 can control the shut height but the shut height |
| can only be changed from the “Slide Adjust” screen. A RECALLED job will |
| NOT change the shut height, although an operator can cause the system to |
| automatically adjust to a new shut height by turning the Slide Adjust OFF/ON |
| switch to the ON position, entering the desired shut height value in the “Slide |
| Setpoint” row, and pressing the “AUTO ADJUST” softkey. OFF means the 5000 |
| will not automatically adjust the shut height, and will ignore any errors from the |
| system. Operators can always manually jog the slide into position through the use |
| of the “JOG UP” and “JOG DOWN” softkeys. These keys appear when the Slide |
| Adjust OFF/ON switch is in the ON position regardless of whether ON, MAN, or |
| OFF is configured. This value should typically be set to ON. |
Shut Height Units | All shutheight parameters and the shut height actual position can be displayed and |
| entered in inches or millimeters. Use the “CHANGE UNIT” softkey to toggle |
| this setting between inches and millimeters. Note that values already entered will |
| be converted to the new unit. |
April 17, 2000 Man ual Versio n 1.0 | 4.8 |