COMMAND SETTING AND OPERATION TIMING
One Shot CMD and actual operation timing
As shown in the following figure, it takes at least about 1 V for the actual isochronous transmission to start after the One Shot command (CSR F0F0061Ch) has been set to the CSR of the camera.
(VDs are the reference signals inside the camera and cannot be observed from outside the camera.)
Set One Shot in this period
VD
1 V
Approx. 8.0 ms
Isochronous
ON
One Shot is executed with an interval of 1 V from V period set
If Shutter is set to the extended exposing mode, isochronous transmission start may delay for the exposure time at maximum in addition to the previous delay.
Do not set a new One Shot command until isochronous transmission completes after the One Shot command has been set to the CSR.
Trigger Mode command and actual operation timing
As shown in the following figure, it takes about 430 ms
Set Trigger ON in this period
VD
1 V
Approx. 430 ms
NORM. until now Trigger Mode from here
Isochronous
Image by external trigger signal is output from here at the earliest
39