Settings and Adjustments 5 Chapter
VCR Menu Operation
6 Press the VTR button on the camcorder or lens.
Test recording starts.
The display changes as shown below during recording. (The hyphen following “At” moves to right.)
At - n At - n... n At -
After about 1 minute, the tape is rewound to the recording start position and playback starts. The following is displayed during playback.
At PLAY
7 Check the recording quality of the playback video on the viewfinder or monitor screen. Check the recording quality of the playback audio from the earphone or headphones.
If the recording quality is poorThere may be some kind of problem whether or not it is detected by the internal check. Refer to the section “Troubleshooting” (page 117) and repeat the test. If the recording quality remains poor, contact your Sony dealer.
When playback ends, the internal check result is displayed and the camcorder enters recording pause mode.
8 After confirming the result (see the next section “Confirming the result”), press the MENU button.
The display window returns to the display shown before the VCR menu.
The result of the internal check is displayed in code as shown in the table below. When a problem is indicated, follow the instructions to check the camcorder and cassette. If no errors can be found, contact your Sony dealer. Also, be sure to check the quality of the playback video and audio (see step 7).
Display | Diagnostic result |
|
|
At good | VCR’s internal operations are normal. If the |
| video and audio recording qualities are |
| normal, the unit is ready for use. |
|
|
At | There may be a problem in the VCR or the |
| cassette. Contact your Sony dealer. |
|
|
At | There may be a problem in VCR’s internal |
| operations or data loading from the tape. |
| Clean the video heads using the |
| Cleaning Cassette (see page 114) and |
| repeat the |
| same, contact your Sony dealer. |
|
|
At | There may be a problem in the link between |
| the camera and VCR sections. If not, correct |
| the error and repeat the |
| result is the same, contact your Sony dealer. |
|
|
At | Check whether the REC/SAVE switch is set |
| to SAVE. If so, repeat the |
| setting the switch to REC or using another |
| cassette whose REC/SAVE switch is set to |
| REC. If the result is the same, contact your |
| Sony dealer. |
|
|
At | Check whether a cassette is inserted. If not, |
| insert a cassette and repeat the |
| If the result is the same, contact your Sony |
| dealer. |
|
|
If the video and audio recording qualities are | |
| normal, the unit is ready for use. However, |
| the unit requires service. It is desirable to |
| consult your Sony dealer. |
|
|
At Abort | The test recording or playback and internal |
| check have aborted (when a tape transport |
| button was pressed during recording or |
| playback or when the tape ended). To |
| resume the |
| button to close the menu and perform the |
| procedure described in the previous section |
| “To perform the |
|
|
96 | Chapter 5 Adjustments and Settings |