Item number

Item

Settable range

Function

110

KEY INHIBIT

 

The enablingor disabling of switchesand buttonscanbe

 

SWITCH

 

independentlyspecifiedthrougheachofthefollowingsub-

 

EFFECTIVE AREA

 

items when item 109 is set to “on”.

 

 

 

 

 

 

Sub items

 

 

 

1

MON./INPUT

[dis]

Specifies whether the INPUT/MONITOR SELECT buttons

 

 

SEL

ena

on the upper control panel are enabled or not.

 

 

 

 

dis : INPUT/MONITOR SELECT buttons are disabled.

 

 

 

 

ena: INPUT/MONITOR SELECT buttons are enabled.

 

 

 

 

 

 

2

CONTROL

[dis]

Specifieswhichswitchesandbuttonsonthecontrolpanelof

 

 

PANEL

edit

thisunitandtheexternalcontrolpanelconnectedtothisunit

 

 

 

ena

are enabled.

 

 

 

 

dis :Allswitchesandbuttonsaredisabled.

 

 

 

 

edit:Theswitchesandbuttonsrelatedtoeditingfunctionare

 

 

 

 

disabled.

 

 

 

 

ena: All switches and buttons are enabled.

 

 

 

 

 

111

VARIABLE SPEED

[off ª–1 to +2 º ]

Sets the the tape speed range during variable-speed (VAR)

 

LIMIT IN KEY

on ( 0 to +1)

playbackonthecontrolpanelofthisunit.

 

PANEL CONTROL

 

off (–1 to +2) : The range of the tape speed is –1 to +2 times

 

 

 

 

normalspeed.

 

 

 

 

on (0 to +1) : The range of the tape speed is 0 to +1 time

 

 

 

 

normalspeed.

 

 

 

 

112

CTL LOCK IN

[off]

CTLlocksthetapetransportduringvariable-speedplayback

 

VAR/SHTL

–1/–0.5/0.5/1.0/2.0

orshuttleplayback.

 

 

 

 

off : CTL does not lock.

 

 

 

 

–1/–0.5/0.5/1.0/2.0: CTL locks the tape transport at speeds

 

 

 

 

of –1, –0.5, 0.5, 1.0, and 2.0 times normal speed.

113

DT MODE

[field ª–1 to +1 º ]

Sets the DT operation mode.

 

 

 

frame

field : (–1 to +1): Enters the field playback mode (Field DT

 

 

 

 

mode) when the tape speed is –1 to +1 times normal

 

 

 

 

speed.

 

 

 

 

Enters the frame playback mode (Flame DT mode) when

 

 

 

 

the tape speed is +1 to +2 times normal speed.

 

 

 

 

frame: Enters the frame playback mode (Frame DT mode).

 

 

 

 

114

POWER-ON MENU

[home menu]

Selects the menu displayed when the unit is powered on.

 

select

TC menu

 

 

 

 

CUE menu

 

 

 

 

PF1 menu

 

 

 

 

PF2 menu

 

 

 

 

ALT+PF1 menu

 

 

 

 

ALT+PF2 menu

 

 

 

 

 

115

KEY BEEP

high

Selects the volume of the key click sound.

 

 

 

low

 

 

 

 

[off]

 

 

 

 

 

116

ALARM BEEP

[high]

Selects the volume of the key click sound.

 

 

 

low

 

 

 

 

off

 

 

 

 

 

117

SCREEN SAVER

3 min

Selects the time after which the screen saver function

 

 

 

10 min

operates.

 

 

 

60 min

 

 

 

 

[off]

 

 

 

 

 

118

INPUT GUARD

[off]

Selects the mode in which the INPUT SELECT buttons on

 

select

on

thefrontpanelswitchvideoandaudioinputs.

 

 

 

 

off: The INPUT SELECT buttons on the front panel can

 

 

 

 

switchthevideoandaudioinputs.

 

 

 

 

on: The INPUT SELECT buttons on the front panel are

 

 

 

 

inhibitedfromswitchingthevideoandaudioinputs.

 

 

 

 

However, it is possible to check the INPUT SELECT

 

 

 

 

display, and to carry out MONITOR SELECT switching.

 

 

 

 

 

Appendix

Appendix A-41