Appendix

Menu List

Other Items (T01~)

The values enclosed in a box are the factory settings.

Item number

Item

Settable range

Function

T01

AUTO REPEAT

[off]

Selectstherepeatingoperationinautomaticediting.

 

MODE

on

off:Automaticeditingisnotrepeated.

 

 

 

on: Automatic editing is repeated. To stop, press the STOP

 

 

 

button.

 

 

 

 

T02

INTERNAL VIDEO

[off]

Selectsthetestsignaloutputbythesignalgeneratorbuilt

 

SIGNAL

COLOR BARS

into the VTR.

 

GENERATOR (HD)

MULTIBURST

off: The test signal is not generated, and the VTR operates

 

 

10 STEPS

normally.

 

 

PULSE & BAR

all other settings: The test signal is output from the VTR. At

 

 

[RAMP]

this time it is also possible to record the signal.

 

 

BLACK

 

 

 

 

 

T03

INTERNAL VIDEO

1035

Selectsthe effective scanning line number of the test signal

 

SIGNAL LINE

[1080]

output by the signal generator built into the VTR.

 

SELECT

 

1035: Sets the effective scanning line number to 1035.

 

 

 

1080: Sets the effective scanning line number to 1080.

 

 

 

Note

 

 

 

 

This setting is only active when the frame frequency of the

 

 

 

unit is 29.97 Hz or 30 Hz.

 

 

 

 

T04

INTERNAL AUDIO

[off]

Selectstheoperationofaudiotestsignaloutput.

 

SIGNAL

silence

off: The audio test signal is not output.

 

GENERATOR

1 kHz sine

silence:Mutesignal.

 

 

 

1 kHz sine: 1 kHz (In this case, a 1 kHz -20 dB FS sine

 

 

 

wave is supplied to all audio inputs.)

Note

• When “silence” or “1 kHz sine” is selected, the AUDIO INPUT/MONITOR SELECT buttons light up.

• When the unit is operated i n the 23.98 PsF or 24 PsF mode with “1 kHz sine” selected, the output signal is 960 Hz.

Note

Setting numbers that start with “T” are reset whenever the power is turned off.

A-64Appendix