@∞ TIME CODE OUT connector (XLR-3-31) Outputs the following time codes according to the VTR operation mode.

In playback mode: Playback time codes

In recording mode: Time codes generated by the internal time code generator, or time codes input to the TIME CODE IN connector.

To select the output signal for the TIME CODE OUT connector, use the 613.TC OUTPUT SIGNAL IN REGEN MODE setting in the VTR SETUP menu.

Setting

Description

off tape

In playback mode, playback time codes are

 

selected, and in recording mode, TCH time

 

code signals are used.

 

 

regene

Playback time codes are regenerated and

 

output only in playback mode when the servo

 

is locked. In all other cases, output is the

 

same as for the “off tape” setting.

 

 

through

The time code signal from the TIME CODE

 

IN connector is output as is. (Used during

 

cascade connections.)

 

(For more information about cascade

 

connections, see 3-1-4 Cascade

 

Connections on page 3-4.)

TIME CODE IN connector (XLR-3-32)

Accepts external time codes for recording to tape. Connect to the time code output connector of the external equipment.