Appendix

Menu List

Item number

Item

Settable range

Function

624

CHARACTER

without BG

Sets the style of text information such as time codes output

 

TYPE

outlined

from the MONITOR connector of HD SDI OUTPUT, the D

 

 

translucent

CONV. OUT (OPTION) COMPOSITE (SUPER) connector,

 

 

[withBG]

the 3 (SUPER) connector of D CONV. SDI OUT (OPTION)

 

 

 

and the PULL DOWN OUT connectors.

 

 

 

withoutBG:Whitecharacters,withnobackground.

 

 

 

outlined:Whitecharactersoutlinedinblack.

 

 

 

translucent:Whitecharactersonagrayscreenbackground.

 

 

 

withBG:Whitecharactersonablackbackground.

 

 

 

Note

 

 

 

 

For the D CONV. SDI OUT (OPTION) connector and D

 

 

 

CONV. OUT (OPTION) COMPOSITE (SUPER)

 

 

 

TYconnector,the“translucent”settingisautomatically

 

 

 

changedto“withBG”.

 

 

 

 

 

625

CHARACTER SIZE

1

Sets the size of text information such as time codes output

 

 

[x 2]

from the MONITOR of HD SDI OUTPUT connector, the D

 

 

3

CONV. OUT (OPTION) COMPOSITE (SUPER) connector,

 

 

 

3 (SUPER) of D CONV. SDI OUT (OPTION) connector and

 

 

 

the PULL DOWN OUT connectors.

 

 

 

1: Normal size.

 

 

 

2: Twice normal size.

 

 

 

3: Three times normal size.

 

 

 

 

 

626

DISPLAY

time data & status

When item 620 is set to “on”, this setting specifies the

 

INFORMATION

time data & UB

contentoftextinformationoutputfromtheMONITOR

 

select

time data & CTL

connector of HD SDI OUTPUT, the D CONV. OUT

 

 

time data & VITC

(OPTION) COMPOSITE (SUPER) connector, the 3

 

 

(SUPER) connector of D CONV. SDI OUT (OPTION) and

 

 

[time data only]

 

 

the PULL DOWN OUT connectors.

 

 

 

 

 

 

time data & status: Timer counter display and status

 

 

 

information.

 

 

 

time data & UB: Timer counter display and user bits.

 

 

 

time data & CTL: Timer counter display and CTL.

 

 

 

time data & VITC: Timer counter display and VITC.

 

 

 

timedataonly:Timercounterdisplayonly.

 

 

 

 

 

627

CHAR WARNING

[off]

When item 626 is set to anything other than time data only,

 

DISPLAY at dual

on

thisitemspecifieswhetherwarningmessagesflashonthe

 

linemode

 

secondlineornot.

 

 

 

off: Warning messages do not flash.

 

 

 

on: If a warning message exists, it flashes.

Notes

• Messages that have been cleared are not displayed. For moreinformationaboutclearingwarningmessages,see “Clearingwarningmessages”onpageA-9.

• When there are multiple warning messages, each message flashes twice before it is replaced by the next message.

A-52Appendix