Controls and Parts of Functions and Locations 2 Chapter

2-3 Connector PanelAUDIO INPUT LEVEL/600termination switches

The termination switches should be set for in ANALOG AUDIO INPUT connector according to the audio input level and input impedance.

Use OFF for low input levels when:

Audio input level is –60 dBu (microphone input) and audio input impedance is high (approximately 20 k)

Use OFF for high input levels when:

Audio input level is +4 dBu (line input) and audio input impedance is high (approximately 20 k)

Use ON for high input levels when:Audio input level is +4 dBm (line input) and audio input impedance is 600!∞ ANALOG AUDIO INPUT connectors (XLR-3-32)Accepts up to five analog audio signal lines (channels 1 to 4 and cue).ANALOG AUDIO OUTPUT connectors (XLR-3-31)Outputs up to five analog audio signal lines (channels 1 to 4 and cue).

CONTROL PANEL connector (15-pin) Connects the control panel through the 15-pin cable when using the control panel is used as a remote controller.

!• REMOTE1-IN (9P)/OUT (9P) connectors (D-sub 9-pin)

Used with the included 9pin remote control cable to connect two HDW-F500 VTRs, or a second HD VTR when a BVE900/910/2000/9000/9100 series BVE Editing Control Unit is used for editing. Used when you edit using two VTRs and the BVE-900/910/2000/ 9000/9100 Editing Control Unit. The REMOTE1-IN and OUT connectors can be used to make a bridge connection.

MONITOR OUTPUT connectors (XLR-3-31) Outputs signals for audio monitoring. These connectors output two signal lines: L and R. Select the signals to be output with the MONITOR SELECT buttons and the AUDIO INPUT/MONITOR SELECT buttons on the upper control panel. A setting can be made so that volume can be controlled with the PHONES volume knob.

For details, see Section 5-1-2, “Selecting Audio Signals”on page 5-2.

VIDEO CONTROL (Digital Video ProcessorControl) connector (D-sub 9-pin)

Connects to the optional HKDV-503 HD Digital Video Controller to enable remote control of the internal digital video processor. Turn off the power before connecting the remote controller.

RS-232C connector (RS-232C serial interface) (D-sub 25-pin)

Receives or transmits RS-232C serial remote control signals and/or VTR status data from/to external equipment. When this connector is being used for communication, the RS-232C indicator on the upper control panel will be lit.

@™ PARALLEL I/O (50P) connector (D-sub 50-pin, with optional BKDW-509)Inputs an external remote control signal.

For details, refer to the Maintenance Manual.

D CONV. SDI (D1/D2 SDI video/audio) (OPTION) OUT connectors (BNC)

Outputs up to three sets of video/audio signals. When the ALT/[F8] (CHARA SUPER) key of the TC menu is set to ON, text data such as time codes are superimposed on the output of connector 3 (SUPER). Selection of D1/D2 output is made using the [F9] (OTHERS CHECK)/[F9] (SYSTEM)/[F3] (D-CONV SDI) button in the MAINTENANCE menu.

Note

This connector is operative only when the optional HKDV-501A HD-SD Converter Board is installed.

PULL DOWN OUT (OPTION) connectors (BNC)

Outputs two sets of 2-3 pull down video/audio signals. When the ALT/[F5] (PD CHARA) key of the TC menu is set to ON, text data such as time codes are superimposed.

Note

This connector is operative only when the optional HKDV-507 HD PULL DOWN Board is installed.

2-16

Chapter 2 Locations and Functions of Parts and Controls