Items Related to the Time Code (601~)

The values enclosed in a box are factory settings.

Item number

Item

Settable range

Function

601

DF/NDF MODE

[drop frame]

Selects the timing mode for the time code generator and the

 

select

non-dropframe

CTLcounter.

 

 

auto

dropframe:dropframemode(“DF”indication)

 

 

 

non-dropframe:non-dropframemode(“NDF”indication)

 

 

 

auto: Drop frame / non-drop frame mode is selected

 

 

 

automatically on the basis of the frame frequency of the

 

 

 

unit. For 29.97 Hz drop frame mode is selected, and for

 

 

 

30 Hz non-drop frame mode is selected. The setting of

 

 

 

the frame frequency mode is carried out with the

 

 

 

[MAINTENANCE]/[F9]/(OTHERS CHECK/SYSTEM)

 

 

 

buttons.

 

 

 

Note

 

 

 

 

• This setting is only active when the frame frequency of the

 

 

 

unit is 29.97 Hz or 30 Hz.

 

 

 

• When the [F7](TCG MODE) key is set to regene, the time

 

 

 

codegeneratorissynchronizedtotheplaybacktimecode,

 

 

 

andthereforethissettingisdisabled.

 

 

 

 

602

TIMER MODE

CTL

Selects the mode for displaying time data.

 

select

[TC]

CTL: During playback the CTL signal recorded on the tape,

 

 

UBIT

orduring recording theCTL signalbeing recorded onthe

 

 

 

tape, is counted, and the tape running time is displayed

 

 

 

inhours,minutes,seconds,andframes.

 

 

 

TC: The time code value read by the time code reader, or

 

 

 

the time code value generated by the time code

 

 

 

generator is displayed. Use item 603. to toggle between

 

 

 

VITC and LTC.

 

 

 

UBIT: The user bits inserted in the playback time code, or

 

 

 

the user bits inserted in the being recorded are

 

 

 

displayed. Use item 603. to toggle between VITC and

 

 

 

LTC.

 

 

 

 

603

TCR MODE select

[LTC]

Selects the time code read by the time code reader during

 

 

auto

playback.

 

 

VITC

LTC: LTC is read.

 

 

 

auto: If the playback speed is from –1/2 to +1/2 normal

 

 

 

speed, VITC is read, and if outside this range LTC is

 

 

 

read.

 

 

 

VITC: VITC is read.

 

 

 

 

604

TAPE TIMER

+/– 12H

Selects whether the CTL counter operates in 12-hour

 

DISPLAY

[24H]

displaymodeor24-hourdisplaymode.

 

 

 

+/–12H: 12-hour display mode

 

 

 

24H: 24-hour display mode

 

 

 

Note

 

 

 

 

In the ±12-hour display, the tens digit of the hours value is

 

 

 

dropped.

 

 

 

 

605

VITC SOURCE

[TCG]

Selects the source for VITC to be written to the AUX data

 

 

V IN

area of video signals.

 

 

 

TCG: Write the signals generated by this unit’s internal time

 

 

 

code generator to the VITC.

 

 

 

V IN: Write the VITC of video signals input to this unit to the

 

 

 

VITC.

Appendix

Appendix A-49