Items Related to the Pull Down Control (A01~)

The values enclosed in a box are the factory settings.

Item number

Item

Settable range

Function

A01

PD TIME CODE

[off]

Sets whether or not to display the pull down time code on

 

DISPLAY

on

the time code display area.

 

 

 

off: Does not display the pull down time code.

 

 

 

on: Displays thepull downtime code.

 

 

 

 

A02

PD PRESET

[24 FRAME MODE]

Selects the time code to be preset. The A frame of the

 

FRAME MODE

30 FRAME MODE

pulldownsequencecanbepreset.

 

 

 

24 FRAME MODE: The 24 frames time code is preset.

 

 

 

30 FRAME MODE: The 30 frames time code is preset.

 

 

 

 

A03

PD

[off]

Specifies whether or not to superimpose time data and

 

SUPERIMPOSED

on

operatingstatusinformationonthesignaloutputfromthe

 

CHARACTER

 

PULL DOWN OUT connector.

 

 

 

off:Noinformationissuperimposed.

 

 

 

on:Informationissuperimposed.

 

 

 

 

A04

PD DF/NDF

[drop frame]

Selects the running mode for the pull down time code to be

 

SELECT

non-dropframe

preset.

 

 

auto

drop frame: Drop frame mode

 

 

 

non-dropframe:Non-dropframemode

 

 

 

auto: The unit switches the running mode (DF/NDF)

 

 

 

automaticallyaccordingtotheframefrequencyofthe

 

 

 

unit. When the frame frequency is 23.976 Hz, the unit

 

 

 

switches to the drop frame mode and switches to the

 

 

 

non-drop frame mode when it is 24 Hz.

 

 

 

 

Appendix