3Press the LEVEL button to select the power level to be set.

The power level is changed in following order.

1/1 t1/2 t1/4 t1/8 t1/16 t1/32 t 1/1 t. . .

For details on setting the power level, refer to page 49.

The flash range check indication of the TEST button (blinks in green) does not work after a photo is taken with the manual flash.

Using custom functions, manual flash may be selected without setting the camera in the M mode (page 44).

TTL flash

Manual flash provides a fixed flash intensity irrespective of the brightness of the subject and the camera setting. TTL* flash measures the light from the subject that is reflected through the lens.

Some cameras enable P-TTL metering, which adds pre-flash to TTL metering, and ADI metering, which adds distance data to the P-TTL metering.

This flash unit defines all P-TTL and ADI metering as TTL flash and the LEVEL lamp [AUTO] on the display panel lights up.

*TTL = through the lens

ADI metering is possible in combination with a lens with a built-in distance encoder. Before using the ADI metering function, check whether your lens has a built-in distance encoder by referring to the specifications in the operating instructions supplied with your lens.

Applications

33GB