[Description on Self-diagnosis Display]

Note : The “Self-diagnosis” data is backed up by the coin lithiumbattery. The data will be lost and initialized when the coin lithium battery is removed.

Display Code

Countermeasure

Cause

Caution Display During Error

 

 

 

 

C:32:01

Change the disk and turn off the main

Defective floppy disk.

DRIVE ERROR

power then back on.

 

 

 

 

 

 

 

 

Replace the floppy disk or “Memory

• The type of floppy disk that cannot be

 

 

used by this machine, is inserted.

 

 

Stick” (FD92).

DISK ERROR

C:13:01

(Such as 2DD)

Format the floppy disk or “Memory

MEORY STICK ERROR

 

• Data is damaged.

 

Stick” (FD92) with the MVC-FD87/

(FD92)

 

• Unformatted disk or “Memory Stick”

 

FD92.

 

 

(FD92) is inserted.

 

 

 

 

 

 

 

 

 

Checking of flash unit or replacement of

Abnormality when flash is being

Flash LED

E:91:01

Flash display

flash unit

charged.

 

Flashing at 3.2 Hz

 

 

 

 

 

 

 

E:61:00

 

 

 

 

Checking of lens drive circuit

When failed in the focus initialization.

E61:10

 

 

 

 

 

 

 

[Power supplying Method]

 

 

Use the AC power adaptor (AC-L10A) when supplying the power to this set.