Symptom

Cause/Solution

 

 

 

The battery

• This is normal and poses no danger.

charging stand and

 

 

the recorder become

 

 

hot during the

 

 

charging procedure.

 

 

 

 

 

 

 

 

While recording

Symptom

Cause/Remedy

 

 

 

The recorder

• The record starting-position setting (“REC-Posi”) is set to

overwrites existing

“From Here”.

 

 

 

materials when record.

, Set “REC-Posi” setting to “From End”.

 

 

 

 

 

The recording starts

• The group recording (“

: REC”) is set to “

: REC ON”.

from the end of the

(You cannot overwrite tracks when “

: REC” is set to “ :

disc even when “REC-

REC ON”.)

 

 

 

Posi” is set to “From

, Set the group recording setting to “

: REC OFF”

Here”.

(page 60).

 

 

 

 

 

 

 

“REC-Posi” (the

• The group recording (“

: REC”) is set to “

: REC ON”.

record-starting point)

, Set the group recording setting to “

: REC OFF”

cannot be set to “From

(page 60), and then set “REC-Posi” to “From Here”.

Here”.

 

 

 

 

 

 

 

Recording cannot be

• Audio sources may not be securely connected.

 

done correctly.

, Disconnect the audio sources once and connect them again

 

(pages 20, 26, 28).

 

 

 

There is no digital signal from the portable CD player.

,When recording digitally from a portable CD player, use the AC power adaptor and disable the anti-skip function (such as ESP) on the CD player (page 22).

The analog recording was made using a connecting cord with an attenuator.

,Use a connecting cord without an attenuator.

Recording level is too small to record (when adjusting the recording level manually).

,Pause the recorder and adjust the recording level (page 31).

The power sources was disconnected or a power outage occurred during recording.

,The recording result is not recorded on the disc. Make recording again.

The premastered MD is inserted.

,Replace to the recordable MD.

The remaining recordable time on the disc is 12 seconds or less (“DISC FULL” appears).

,Replace the disc.

78