Appendix
Items Relating to Prerolling (Nos. 401 to ...)
Item number | Item | Setting | Function |
401 | FUNCTION MODE | [stop] | Selects the operation mode that the VTR changes to after |
| AFTER | still | completing a cue up operation. |
|
|
| stop: Enters stop mode. |
|
|
| still: Enters |
|
|
| Note |
|
|
|
| When | setting the standard constant on the editor and |
|
|
| control the unit, set to “stop”. | |
|
|
|
| |
403 | CUEUP BY TC | capstan only | This setting is only active when item 602 is set to “TC” or | |
|
| [reel/capstan] | “UBIT”. | |
|
|
| capstan only: The tape runs with the pinch ON state during | |
|
|
| cue up. (The maximum tape speed is ten times normal | |
|
|
| tape speed.) | |
|
|
| reel/capstan: The tape runs with the pinch OFF state | |
|
|
| during cue up. When the tape nears the cue up point | |
|
|
| and tape speed drops to slow, the pinch turns ON. | |
|
|
|
| |
404 | CUEUP BY CTL | [capstan only] | This setting is only active when item 602 is set to “CTL”. | |
|
| reel/capstan | capstan only: The tape runs with the pinch ON state during | |
|
|
| cue up. (The maximum tape speed is ten times normal | |
|
|
| tape speed.) | |
|
|
| reel/capstan: The tape runs with the pinch OFF state during | |
|
|
| cue up. When the tape nears the cue up point and tape | |
|
|
| speed drops to slow, the pinch turns ON. | |
|
|
| When this unit is controlled by an editor | |
|
|
| 9100, etc), and the setting is “reel/capstan”, cue up | |
|
|
| operations are done at high speed. | |
|
|
| Select “capstan only” when editing precision has priority. | |
|
|
|
| |
405 | CUE MENU | [page mode] | Selects the default mode when the CUE menu is opened. | |
| DEFAULT MODE | extend mode | page mode: PAGE mode | |
| select |
| extend mode: EXTEND mode | |
|
|
|
| |
406 | CUE MENU | [0 sec] | Sets the preroll time for a cueing up operation from the | |
| PREROLL OFFSET |
| CUE menu. | |
|
| 30 sec |
|
|
152 Menu List