Items Relating to Digital Processing (Nos. 902 to ...)

 

 

Item number

Item

Setting

 

Function

 

 

902

FREEZE MODE

[field]

 

 

Specifies the freeze (still-picture) mode and freeze timing

 

 

 

 

field1

 

 

during manual freezing (by REMOTE 1-IN(9P) or REMOTE

 

 

 

 

field2

 

 

2 PARALELL I/O(50P) connector or on the control panel) or

 

 

 

 

frame1+2

 

automatic freezing.

 

 

 

 

frame2+1

 

field: Freezes the odd or even field, depending on the

 

 

 

 

 

 

 

 

timing in freeze mode.

 

 

 

 

 

 

 

 

field1: Freezes the first (odd) field

 

 

 

 

 

 

 

 

field2: Freezes the second (even) field

 

 

 

 

 

 

 

 

frame1+2: Freezes the first and the subsequent second

 

 

 

 

 

 

 

 

field

 

 

 

 

 

 

 

 

frame2+1: Freezes the second field and the subsequent

 

 

 

 

 

 

 

 

first field

 

 

 

 

 

 

 

 

In the case of freezing in playback modes other than

 

 

 

 

 

 

 

 

normal playback, the picture is frozen in frame mode only

 

 

 

 

 

 

 

 

when dynamic tracking is performing a frame operation.

 

 

 

 

 

 

 

 

The picture is frozed in field mode when dynamic tracking is

 

 

 

 

 

 

 

 

not operating.

 

 

 

 

 

 

 

 

The frozen picture does not change even if you change this

 

 

 

 

 

 

 

 

setting during freeze mode. The change to this setting

 

 

 

 

 

 

 

 

becomes effective the next time the VTR outputs a still

 

 

 

 

 

 

 

 

picture.

 

 

 

 

 

 

 

 

When the stop freeze function is enabled, regardless of the

 

 

 

 

 

 

 

 

setting of this item, the picture is frozen in frame mode only

 

 

 

 

 

 

 

 

when dynamic tracking is performing a frame operation, or

 

 

 

 

 

 

 

 

is frozen in field mode when dynamic tracking is performing

 

 

 

 

 

 

 

 

a field operation or when it is not operating.

 

 

 

 

 

 

 

903

FREEZE CONTROL

[momentary]

Determines the freeze operation control by button

 

 

 

FROM KEY PANEL

latch

 

 

operations.

 

 

 

 

 

 

 

 

momentary: The picture is frozen only while the button is

 

 

 

 

 

 

 

 

held down.

 

 

 

 

 

 

 

 

latch: The picture is frozen when the button is pressed, and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

remains frozen when the button is released.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The fozen picture is cancelled when the button is pressed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Appendix

 

 

 

 

 

 

again.

 

 

 

 

 

 

Freezing in odd or even (first or second) field is specified

 

 

 

 

 

 

 

 

Button operations

 

 

 

 

 

 

 

 

by item 902. Distinction between the first or second field,

 

 

 

 

 

 

 

 

follows the distinction in the reference signal.

 

 

 

 

 

 

 

 

905

STOP FREEZE

disable

 

Enable or disables the stop freeze function.

 

 

 

CONTROL

[enable]

 

 

 

 

 

 

 

 

 

 

 

 

910

ACTIVE LINE 1035

[1080

 

1035

$CONV%]

Selects the conversion mode of the effective scanning line

 

 

 

CONVERT MODE

 

k

 

number.

 

 

 

1080k1035(CROP)

 

 

 

 

1080k1035(CONV): Convert the effective scanning line

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

number from 1080 to 1035 preserving the aspect ratio

 

 

 

 

 

 

 

 

of the image.

 

 

 

 

 

 

 

 

1080k1035(CROP): Convert the effective scanning line

 

 

 

 

 

 

 

 

number from 1080 to 1035. The four sides of the image

 

 

 

 

 

 

 

 

are cropped, then it is horizontally expanded.

 

 

 

 

 

 

 

 

 

 

911

ACTIVE LINE 1080

[1080

 

1035

$CONV%]

Selects the conversion mode of the effective scanning line

 

 

 

CONVERT MODE

 

k

 

number.

 

 

 

1035k1080(PANEL)

 

 

 

 

1035k1080(CONV): Convert the effective scanning line

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

number from 1035 to 1080 preserving the aspect ratio

 

 

 

 

 

 

 

 

of the image.

 

 

 

 

 

 

 

 

1035k1080(PANEL): Convert the effective scanning line

 

 

 

 

 

 

 

 

number from 1035 to 1080. The 1035 lines of the

 

 

 

 

 

 

 

 

image are inserted into the 1035 lines of 1080 lines,

 

 

 

 

 

 

 

 

then it is horizontally compressed.

 

 

 

 

 

 

 

 

 

172 Menu List