Replacing the Lamp

The lamp used for the light source has a certain lifespan. When the lamp dims, the color balance of the picture becomes strange, or “Please replace the Lamp/Filter. End of Lamp/Filter life. Lamp off in 1 min.” appears on the screen, the lamp may be exhausted. Replace the lamp with a new one (not supplied) without delay.

Use an LMP-H400 Projector Lamp as the replacement lamp.

The air filter is supplied with the LMP-H400 Projector Lamp. When you replace the lamp, it is also time to replace the air filter.

Whenever you replace the lamp, be sure to replace the air filter with a new one.

For detailed information on how to replace the filter, see “Replacing the Air Filter” on page 67.

When replacing the lamp after using the projector

Turn off the projector, then unplug the power cord. Wait for at least an hour for the lamp to cool.

Caution

The lamp remains hot after the projector is turned off with the ?/1 key. If you touch the lamp, you may burn your fingers.

When you replace the lamp, wait for at least an hour for the lamp to cool.

Do not touch the surface of the lens. If you touch it, wipe off the fingerprints with a soft cloth.

Pay special attention to replacing the lamp when the projector is installed on the ceiling.

1 Turn off the projector and unplug the AC power cord.

2 Place a protective sheet (cloth) beneath the projector.

Note

Be sure that the projector is placed on a stable surface.

3 While holding up the cover release lever on the right, slide the top cover until it stops.

Cover release lever

 

 

4 Loosen the screw on the lamp

Others

cover with a Philips screwdriver,

and then open the lamp cover.

 

 

 

 

 

 

 

 

 

Note

Be sure to use a Philips screwdriver with a shaft length of 130 mm (5 1/8 inches) or more when replacing a projector lamp.

Replacing the Lamp 63 GB