StratoSteam Countertop Steamer
Models STRG-3D and STRG-5D
FIRE HAZARD FOR YOUR SAFETY
SAFETY PRECAUTIONS
DANGER
BURN HAZARD
Location of Serial Plates
INTRODUCTION
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
SPECIFICATIONS
TOTAL DISSOLVED SOLIDS TDS 60 PPM OR LESS
CONNECTION ¼” COMPRESSION, COLD WATER PRESSURE 30 TO 60 PSI
HARDNESS 2 GRAINS 35 PPM OR LESS pH 7.0 to
MAXIMUM FILL CAPACITY 0.87 GALELECTRIC CABLE ENTRY HOLE
GAS PRESSURE REQUIREMENTS
ELECTRICAL REQUIREMENTS
WATER REQUIREMENTS
DRAIN REQUIREMENTS
OPERATION
NOTICE WATER SPECIFICATION
Problem
Possible Causes and Solutions
Power Light
Timer
Thermometer
Control Lever
PAGE 9 OF
COOKING TIPS
SUGGESTED COOKING TIMES
DAILY CLEANING AND MAINTENANCE
CLEANING & MAINTENANCE
STAINLESS-STEEL SURFACES
PERIODIC DE-LIMING AS NEEDED
PAGE 12 OF
PAGE 13 OF
INSTALLATION
Attach Legs
IMMEDIATELY INSPECT FOR SHIPPING DAMAGE
STEP 2B ATTACH TO COUNTERTOP
Installation on Countertop
STEP 2C MOUNTING ON CABINET BASE
STEP 2D STACKING TWO STEAMERS
STEP 3 DRAIN CONNECTION
Location of Connections and Vents
Water Connection
Water Drain
STEP 4 WATER CONNECTION
STEP 5 GAS CONNECTION
TESTING THE GAS SUPPLY PIPING
Electrical Connection
STEP 9 SHUT-DOWN AND WIPE-CLEAN STEAMER
STEP 7 CHECK THE INSTALLATION
STEP 8 CHECK STEAMER OPERATION
SERVICE
Troubleshooting Flowchart, Procedure, or Wiring Diagram
TROUBLESHOOTING FLOWCHARTS, PROCEDURES, AND WIRING DIAGRAMS
HOW THE STEAMER OPERATES
PAGE 23 OF
How the Steamer Operates
DISCONNECT POWER AT CIRCUIT BREAKER
Steamer Not Heating Up, “Power” Light Is Not Lit
DISCONNECT POWER AT CIRCUIT BREAKER
voltage 120, 208, 220, or
DISCONNECT POWER AT CIRCUIT BREAKER
DISCONNECT POWER AT CIRCUIT BREAKER
Check for loose or broken wires see wiring diagram
Is water level at
DISCONNECT POWER AT CIRCUIT BREAKER
Buzzer Does Not Come On When Timer Runs Out
PAGE 26 OF
PAGE 27 OF
Hot Surface Ignitor Glows Red, But Burners Not On
Hot Surface Ignitor Does Not Glow Red
when operating, should draw
Is there 24V from ignitor
Is gas pressure at least 4” WC for
Not All Burners Ignite
natural gas and at least 11” WC for
propane?
valve?
Burner Lights But Goes Out Within a Few Seconds
Possible Cause
Symptom
Cure
burners do not come on when
1. DISCONNECT POWER AT CIRCUIT BREAKER
Power Switch Check
1. DISCONNECT POWER AT CIRCUIT BREAKER
Timer and Buzzer Check
1. DISCONNECT POWER AT CIRCUIT BREAKER
Door Switch Check
PAGE 34 OF
High-Limit Thermostats Check
2. DISCONNECT POWER AT CIRCUIT BREAKER
Water Solenoid Check
1. DISCONNECT POWER AT CIRCUIT BREAKER
PAGE 36 OF
PAGE 37 OF
Wiring Diagram for 208/220/240 Volt and 115 Volt Models
HIGH LIMIT TSTATS
PARTS
Parts Diagram
Structural Parts
Structural Parts
See parts list on previous page
PAGE 40 OF
NYLON WASHER, 1/4 X 1/2 X 1/8
Door Assembly Parts
PIN, .250 DIA, SS, CAST LATCH STEAMER
Door Switch Parts
PAGE 42 OF
1-17
Control Panel Parts
Not shown on drawing
IR BURNER ASSEMBLY, PROPANE
Burner Assemblies, Thermocouple, and Ignition Module
BURNER BOX, STRATOSTEAM GAS
Quantity of part used may depend on model STRE-3D or SRTE-5D
FITTING, 1/8 NPT X 1/4 CC STRAIGHT 1/4 M X 3/8 CC
Water Train Parts
PAGE 45 OF
See parts list on
Water-Train Parts
previous page
PAGE 47 OF
Cabinet Base Parts
PAGE 48 OF
Cabinet-Base Parts
PAGE 49 OF
STRATOSTEAM COUNTERTOP STEAMER
StratoSteam Countertop Steamer Models STRG-3D and STRG-5D