Southbend STRG-3D, STRG-5D Not All Burners Ignite, Is gas pressure at least 4” WC for, propane?

Models: STRG-3D STRG-5D

1 50
Download 50 pages 48.74 Kb
Page 29
Image 29
Not All Burners Ignite

STRATOSTEAM COUNTERTOP STEAMER

SERVICE

Figure 16

Not All Burners Ignite

 

Not all burners ignite.

 

 

Is gas pressure at least 4” WC for

 

No

Yes

natural gas and at least 11” WC for

 

 

 

 

 

propane?

 

Adjust gas pressure to correct

level.

No

Is orifice correctly aligned with burner?

Yes

 

 

 

Align burners and orifices.

Make sure burner orifice are clear

and the correct size.

Natural Gas #54, Propane #64

are installed.

OWNERS MANUAL 1185290

PAGE 29 OF 50

Page 29
Image 29