STRATOSTEAM COUNTERTOP STEAMER

SERVICE

Figure 21

High-Limit Thermostats Check

1.Allow cavity bottom to cool before performing this test.

2.DISCONNECT POWER AT CIRCUIT BREAKER.

3.Remove left side panel.

4.Disconnect wire B4 from left (as shown above) high-limit thermostat.

5.Disconnect wire B5 from right high-limit thermostat.

6.Disconnect remaining high-limit thermostat wires B11 and B12.

7.Test each high-limit thermostat for continuity (as shown above). There should be continuity when the thermostat is cool. Replace as necessary.

8.Reconnect wires.

OWNERS MANUAL 1185290