Water Drain

STRATOSTEAM COUNTERTOP STEAMER

INSTALLATION

Figure 7

 

Water Drain

 

 

Stand

 

Pipe

 

90°

Air Gap

 

Air Gap

Air Gap

 

Floor Drains

STEP 4: WATER CONNECTION

 

STEP 4: WATER CONNECTION WARNING

Do not connect steamer to a hot water line. A hot water connection will damage the steamer.

NOTICE

To meet warranty requirements, the supply water must meet the following specifications:

Pressure

30 to 60 PSI (205 to 410 kPa)

Total Dissolved Solids (TDS)

60 PPM or less

Hardness

2 grains (35 PPM) or less

pH

7.0 to 7.5

Connect a cold water line to the water inlet strainer on the back of the steamer, as shown in Figure 6. The connector on the steamer is a 1/4" compression fitting.

NOTE: To facilitate cleaning, and allow access to rear of the steamer, flexible connections are recommended. A shut off valve at (or near) the rear of the steamer is highly recommended. Also, an accessible water filter is recommended to help keep water quality within the requirements described above. See Figure 8 below.

Figure 8

 

Water Connection

 

Cold

 

Water

Steamer

Supply

 

Shut Off

Filter

Valve

 

OWNERS MANUAL 1185290